Genuine AirTAC valve manifold, order code 200M-13F from the 4AM range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The AirTAC 200M manifold groups 4A200 air-piloted valves into a single bank fed by one supply and one common exhaust, which cuts piping work and makes faults easier to trace. This order code is built with thirteen stations and PT ports, since the code carries no G or T thread letter.
Thirteen stations give a body length A of 44 mm plus 23 mm for each of the twelve extra stations, so 320 mm overall. The 1/4 inch supply port P feeds the whole bank, the fluid must be air filtered to 40 um, and the working range is -20 to +70 C. The package contains the manifold, seals and screws; any station left without a valve is closed with the P-200M-R2 blank plate kit ordered separately.
| Order code | 200M-13F |
|---|---|
| Product | Valve Manifold |
| Manifold | 200M (for 4A200) |
| Stations | 13 stations |
| Thread | PT |
| Models | 100M / 200M / 300M / 400M |
|---|---|
| For valves | 4A100 / 4A200 / 4A300 / 4A400 |
| Maximum stations | 16 / 16 / 12 / 8 |
| Supply port P | 1/4" / 1/4" / 3/8" / 1/2" |
| Length A | 100M 38 + 19 × (n-1) mm; 200M 44 + 23 × (n-1) mm; 300M 52 + 28 × (n-1) mm; 400M 61 + 35 × (n-1) mm |
| Fluid | Air, filtered to 40 µm |
| Temperature | -20 to +70 °C |
| Included | Manifold, seals and screws |
| Blank plate | Kit P-□00M-R2 (separate) |
Source: AirTAC 4A manifold datasheet (p.124), ordering code, specifications and dimensions.
Pick 200M-13F when thirteen 4A200 valves, or fewer closed with blank plates, share one bank; one station down is 200M-12F and one up is 200M-14F, within the 16-station ceiling of the 200M series. Compared with 100M, which spaces 4A100 valves only 19 mm apart, 200M uses a 23 mm pitch to suit the larger 4A200 bodies, and both share the 1/4 inch supply port that 300M (3/8 inch) and 400M (1/2 inch) do not.
Cluster the 4A200 valves that drive clamps and ejectors at thirteen workstations, all fed from the single 1/4 inch PT supply port.
Run sealing, cutting and pusher cylinders from one compact 320 mm long bank instead of thirteen individually piped valves.
Group the valves switching diverters and stops along a line; the shared exhaust keeps silencing and fault tracing simple.
Thirteen stations for 4A200 valves, PT threads (no G or T letter in the code), 1/4 inch supply port P, length A of 320 mm (44 mm plus 23 mm per extra station), series maximum of 16 stations, air filtered to 40 um, and a temperature range of -20 to +70 C.
The order includes the manifold, seals and screws. Any station kept without a valve is closed with the P-200M-R2 blank plate kit, which is ordered separately per the manifold datasheet.