The AirTAC Airtac 3V1 Solenoid Valve 3V106BI11F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
3V106BI11F is an 11-station manifold assembly of AirTAC 3V1 direct-acting 3/2 solenoid valves. Each PT1/8-ported position feeds or vents a single line, so it drives single-acting cylinders, air-blow jets, clamps or pilots a larger valve, then springs back to its fixed initial state when power drops. Every station runs on a DC24V coil drawing only 3.0 W.
Instead of eleven separate bodies and eleven wiring runs, the valves share one common base, and each coil terminates in a pre-wired flying lead rather than a DIN socket, which keeps cabinet looms short. Coils meet IP65 (DIN 40050) and a manual override is fitted for commissioning. Supply air must be filtered to 40 um or finer; lubrication is not required.
| Model | Airtac 3V1 Solenoid Valve 3V106BI11F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 11F | 11 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Cycles single-acting swing clamps on an engine-block machining fixture, one station per clamp, the spring return venting the line between cycles.
Fires short air pulses through a nozzle to clear paste residue from PCB placement heads, with direct-acting response and no pilot air needed.
Sends an air pilot signal to a bigger diaphragm valve on a water-treatment skid, one manifold station reserved per pilot point.
3V1 is the smallest and lowest-power body in the AirTAC 3V range, and its flow coefficient is not published - so for flow-critical duties confirm the sizing with us before ordering. If you need more flow, step up to 3V2 (1/8 or 1/4 ports, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or 3V3 (1/4 port, Cv 0.62). Where manifold density matters more than flow, 3V2M is the alternative; a double-acting cylinder, however, needs the 5-port AirTAC 4V series.
Before ordering, match five points: port (M5 or 1/8); thread (PT is standard on this family, with G and NPT as order options); coil voltage; electrical entry (DIN plug or flying lead); and the number of manifold stations, built from 1 to 20.
Confirm before you order
Operating pressure 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C, DC24V coil power 3.0 W, protection IP65 (DIN 40050), 11 stations on a common base with PT1/8 ports. A flow coefficient (Cv) is not published for the 3V1 body, so confirm flow-critical sizing with us. Elsewhere in the family: AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC12V 2.5 W.
Each station is a 3/2 valve with three ports (supply, outlet, exhaust) and two states: it either feeds the outlet or vents it. That suits single-acting spring-return cylinders, air blow, clamping and piloting a larger valve. It will not drive a double-acting cylinder, which requires a 5-port valve such as the AirTAC 4V series. The initial state is a single fixed condition - confirm it on the datasheet.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.