verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 3V1 · 3/2-Way Solenoid Valve

Airtac 3V1 Solenoid Valve 3V106BI4F

The AirTAC Airtac 3V1 Solenoid Valve 3V106BI4F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port size1/8 in
  • Coil voltageDC24V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations4
  • Series3V1
$83.14 $88.88Save 6% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V1 Solenoid Valve 3V106BI4F

Four 3/2 valves, one base: 3V106BI4F is a four-station AirTAC 3V1 manifold with PT1/8 ports, direct-acting single-solenoid construction and spring return on every station. The DC24V coils draw 3.0 W each - light enough for small PLC transistor outputs - and the flying-lead entry brings each coil out on a pre-wired lead, so no DIN plugs are ordered or lost.

Each station controls its own line independently: it pressurises the outlet or dumps it to exhaust. IP65 (DIN 40050) coil housings shrug off dust and splash, a manual override on every station lets you jog outputs during setup, and the air only needs 40 um or finer filtration - lubrication is not required. Supplied in a single fixed initial state per valve; confirm it on the datasheet.

Airtac 3V1 Solenoid Valve 3V106BI4F Technical Specifications

ModelAirtac 3V1 Solenoid Valve 3V106BI4F
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port size1/8 in
ThreadPT
Coil voltageDC24V
Electrical entryFlying lead (lead-out wire type)
Coil power3.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: Airtac 3V1 Solenoid Valve 3V106BI4F

3V1Body — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
DC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
4F4 stations in one assembly.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V1 Solenoid Valve 3V106BI4F Is Used

precision_manufacturing

Indexing dial ejectors

Four blow jets eject parts from fixtures on a rotary indexing machine, one dedicated valve per jet at 3.0 W of coil draw.

science

Automated lab sampler purge

Analyser sample probes get an air purge between runs, with four independent lines handled by one compact PT1/8 manifold block.

cable

Junction-box machine wiring

Flying leads land straight onto terminal blocks inside tight electrical cabinets where plug-in DIN connectors will not fit.

Is the Airtac 3V1 Solenoid Valve 3V106BI4F the Right Part?

Check the flow first: AirTAC publishes no Cv for 3V1, so if your cycle depends on flow rate, tell us the duty before you buy. More capacity comes from 3V2, which spans 1/8 in and 1/4 in ports, offers selectable NC or NO function, Cv 0.18-0.19 and a vacuum rating, or from 3V3 at 1/4 in with Cv 0.62. If packaging density outranks flow, the 3V2M manifold body is the alternative to weigh. Double-acting cylinders need 5 ports - the AirTAC 4V series covers that job.

For this four-station code, lock down: the port (M5 or 1/8 in), thread style (PT standard on 3V1, with G and NPT available to order), coil voltage, entry style (plug-in DIN or this flying lead), and the station count, from a single valve up to 20.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V1 Solenoid Valve 3V106BI4F FAQ

Operating pressure 0-0.8 MPa (0-114 psi); medium temperature -20 to 70 C; coil housings IP65 (DIN 40050). Rated coil power across the range: AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W - the coils fitted here are DC24V. Function is 3/2, direct-acting, single solenoid, spring return. AirTAC publishes no Cv or effective area for 3V1, so treat flow as confirm-from-datasheet.

The I segment in 3V106BI4F means lead-out wire entry: each coil is wired through a pre-fitted flying lead rather than a plug-in DIN socket, which suits terminal-block or conduit landing work. Both entry styles reach IP65; 3V1 codes without the I use the DIN plug. Choose whichever wiring method your panel builder prefers.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V1 Solenoid Valve 3V106BI4F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V106BI4F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.