The AirTAC Airtac 3V1 Solenoid Valve 3V106BI8F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Eight 3/2 valves, one manifold: 3V106BI8F packs a full bank of direct-acting, spring-return stations into a single valve row. Two states, three ports per station - supply, outlet, exhaust - so each position either pressurizes its line or vents it. With eight DC24V coils at 3.0 W apiece, the total coil load is 24 W, light enough for most 24 V panel supplies.
The I in the code means flying-lead entry: every coil carries its own pre-wired lead-out instead of sitting on a DIN socket, which suits machines where the valve bank sits inside a sealed enclosure wired to a terminal rail. Each station has a manual override for set-up, coil protection is IP65 (DIN 40050), and the 1/8in ports carry the PT thread that is the manufacturer default for this body.
| Model | Airtac 3V1 Solenoid Valve 3V106BI8F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 8F | 8 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A single-acting gate cylinder at each of eight divert points is fed and vented by its own station; spring return drops the gate the moment the coil drops out.
Eight single-acting clamp cylinders lock a gearbox housing for machining; the manual override lets a setter release any clamp without applying power.
Each station routes supply to one test port of an eight-way leak-test fixture, and 3.0 W coils keep the 24 V rail of the test controller well within budget.
Size this bank honestly: 3V1 is the smallest body and the lowest coil draw in the 3V family, and it publishes no Cv, so for flow-critical work send us your flow target and we will confirm the fit. Need more flow? Move up to 3V2 (1/8in and 1/4in ports, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or 3V3 (1/4in, Cv 0.62). If your real priority is the densest possible manifold rather than flow, 3V2M was built for it. A double-acting cylinder needs a 5-port valve, so route that job to the AirTAC 4V series.
Confirm five things against your drawing: M5 or 1/8in port, PT thread (G and NPT are catalogue options to order), coil voltage, DIN plug versus flying lead, and the number of stations - 1 to 20 are available, with this SKU fixed at 8.
Confirm before you order
Eight 3/2 direct-acting, spring-return stations sharing one manifold. Pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, IP65 (DIN 40050). Each DC24V coil draws 3.0 W; across the 3V1 range AC220V and AC110V coils are 4.5 VA, AC24V is 5.0 VA and DC12V is 2.5 W. Air must pass a 40 um or finer filter and no lubricator is needed. One honest caveat: AirTAC publishes no Cv for 3V1, so verify flow with us.
The I in 3V106BI8F means lead-out wiring: each coil exits on its own pre-wired lead instead of plugging onto a DIN socket, so all eight stations land on a common terminal rail - often tidier inside sealed enclosures than eight separate plugs. Coil rating is 3.0 W per station at DC24V, ports are 1/8in PT (G or NPT exist as order options), and the manifold can be ordered in any size from 1F to 20F.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.