verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 3V1 · 3/2-Way Solenoid Valve

Airtac 3V1 Solenoid Valve 3V106E-AM

The AirTAC Airtac 3V1 Solenoid Valve 3V106E-AM is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port size1/8 in
  • Coil voltageAC24V
  • Electrical entryDIN plug (DIN socket type)
  • Series3V1
$26.39 $30.73Save 14% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V1 Solenoid Valve 3V106E-AM

The AirTAC 3V106E-AM is an individual 3/2-way direct-acting solenoid valve with 1/8in PT ports and an AC24V coil rated at 5.0 VA. Energising the solenoid switches the outlet between supply and exhaust; the spring returns it when power is cut, so one small valve can feed or vent a single line. That suits single-acting cylinders, air blow-off, clamping and piloting a larger valve.

The 24V AC coil keeps control wiring simple in panels that run a standard AC control transformer, and the DIN plug socket lets you disconnect the valve without unwiring it. The IP65 (DIN 40050) coil enclosure resists dust and splash, a manual override is fitted to help commissioning, and the valve runs on air filtered through a 40 um or finer element with no lubrication required.

Airtac 3V1 Solenoid Valve 3V106E-AM Technical Specifications

ModelAirtac 3V1 Solenoid Valve 3V106E-AM
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port size1/8 in
ThreadPT
Coil voltageAC24V
Electrical entryDIN plug (DIN socket type)
Coil power5.0 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: Airtac 3V1 Solenoid Valve 3V106E-AM

3V1Body — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
Electrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V1 Solenoid Valve 3V106E-AM Is Used

bolt

Clamp fixture on a CNC milling vise

The valve exhausts the single-acting clamp cylinder when the cycle ends, letting the spring retract the jaw; the manual override proves the clamp position before production starts.

cable

Wiring test bench for control panels

An AC24V coil wired from the bench transformer energises a blow nozzle that clears chips from terminals under test, and the spring return shuts the jet the moment the coil drops out.

valve

Pilot stage on a water-treatment skid

A small 3/2 valve sends an air pilot signal to a larger process valve actuator; at 5.0 VA the solenoid load is trivial for the skid's 24V AC control circuit.

Is the Airtac 3V1 Solenoid Valve 3V106E-AM the Right Part?

3V1 is the smallest, lowest-power body in the AirTAC 3V range, and no Cv is published for it, so settle any flow-critical duty with us before ordering. Step up to 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or 3V3 (1/4in, Cv 0.62) when a job needs more flow, and pick 3V2M where a dense manifold matters more than flow. Match five points to this exact code: 1/8in port with PT thread (G and NPT are catalogue options to order), AC24V coil, DIN plug entry, and a single valve rather than a manifold station count. For a double-acting cylinder you need a 5-port AirTAC 4V valve instead.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V1 Solenoid Valve 3V106E-AM FAQ

It is a 3/2 direct-acting, single-solenoid, spring-return valve with 1/8in PT ports. Pressure range is 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C, and the coil is IP65 (DIN 40050). Coil power depends on voltage: AC220V and AC110V draw 4.5 VA, AC24V draws 5.0 VA, DC24V 3.0 W and DC12V 2.5 W - this SKU is the 5.0 VA AC24V version. AirTAC publishes no Cv or effective area for the 3V1 body, so confirm any flow-critical duty with us.

Three ports, two states: it either feeds the outlet or vents it to exhaust. That fits single-acting (spring-return) cylinders, clamps, air blow-off and piloting a larger valve. It cannot switch a double-acting cylinder - that needs a 5-port AirTAC 4V valve. The valve arrives in one fixed initial state; confirm it on the datasheet before wiring your safety logic.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V1 Solenoid Valve 3V106E-AM

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V106E-AM and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.