AirTAC 3V1 · 3/2-Way Solenoid Valve

Airtac 3V1 Solenoid Valve 3V106F3F

The AirTAC Airtac 3V1 Solenoid Valve 3V106F3F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryDIN plug (DIN socket type)
  • Stations3
  • Series3V1
$63.86 $69.13Save 7% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V1 Solenoid Valve 3V106F3F

The 3V106F3F groups three 1/8in PT direct-acting 3/2 valves onto one shared base, so a single mounting footprint replaces three separate bodies and their individual plumbing. Every valve controls one line - feed it or vent it - which fits single-acting cylinders, clamps, blow-off or pilot service.

Each DC12V coil takes only 2.5 W, so three valves together stay comfortably within reach of a small switch-mode 12 V supply. Coils are protected to IP65 (DIN 40050), a manual override is fitted to every station for commissioning, and the DIN plug connection lets a pre-wired harness be lifted off during service. Order the genuine AirTAC part and confirm availability through our RFQ.

Airtac 3V1 Solenoid Valve 3V106F3F Technical Specifications

ModelAirtac 3V1 Solenoid Valve 3V106F3F
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryDIN plug (DIN socket type)
Coil power2.5 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: Airtac 3V1 Solenoid Valve 3V106F3F

3V1Body — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
Electrical entry: I = flying lead, otherwise a DIN plug.
3F3 stations in one assembly.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V1 Solenoid Valve 3V106F3F Is Used

precision_manufacturing

Rotary index-table dwell clamps

Three spring-return dwell cylinders around a rotary indexing table are each fed and vented by one station, holding parts only while the 12 V signal is present.

air

PCB blow-off before reflow

One station drives a narrow air nozzle that clears dust from populated boards, while a second pilots a hold-down and the third vents a single-acting ejector.

settings_input_component

12V PLC cabinet pilot signals

A compact control cabinet uses the three valves as pilot stages that trigger larger process valves, all at 2.5 W per coil so the panel PSU barely notices.

Is the Airtac 3V1 Solenoid Valve 3V106F3F the Right Part?

Because the 3V106F3F puts three circuits on one base, check the five match points first: port (M5 or 1/8in), thread (PT is the family standard, with G and NPT as catalogue options to order), coil voltage, entry style (DIN plug or flying lead) and station count. AirTAC publishes no Cv for the 3V1 body, so if a duty is flow-critical, confirm it with us before ordering. When a single circuit needs more flow, move up to the 3V2 (1/8in and 1/4in, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or the 3V3 (1/4in, Cv 0.62); if dense manifolding rather than flow is the goal, 3V2M is the dedicated choice. Double-acting actuators belong on the 5-port AirTAC 4V series, not here.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V1 Solenoid Valve 3V106F3F FAQ

Operating pressure 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C, DC12V coil power 2.5 W per valve, protection IP65 (DIN 40050), air filtered to 40 um or finer, no lubrication needed. Note that AirTAC does not publish a Cv or effective area for the 3V1 body - confirm flow with us for critical duties.

The 3V106F3F coils run on 12 V DC at 2.5 W each, which suits battery-backed cabinets, mobile machines and low-voltage control panels. The DIN plug connection lets each coil be disconnected without disturbing the wiring, and the coil housing carries IP65 (DIN 40050) protection. Pressure range is 0-0.8 MPa (0-114 psi) with media from -20 to 70 C.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V1 Solenoid Valve 3V106F3F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V106F3F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.