The AirTAC Airtac 3V1 Solenoid Valve 3V106FI5F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V106FI5F is built around AirTAC's 12 V DC coil, which draws just 2.5 W per station - low enough for battery-backed or vehicle-derived supplies on machines where a mains rail is unwanted. Five direct-acting 3/2 valve units share one manifold base with 1/8in PT ports.
Functionally, each station either pressurises its outlet or exhausts it, and the spring sets the state whenever the coil de-energises. Flying leads come out of each coil for direct hookup, the IP65 housing keeps dust and splash out, and a manual override lets you jog every station during commissioning - handy for proving each output before go-live. Product is genuine AirTAC, quoted through our RFQ desk.
| Model | Airtac 3V1 Solenoid Valve 3V106FI5F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 2.5 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 5F | 5 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A juice filler kicks under-filled bottles off each lane; five 3/2 stations pulse single-acting ejector cylinders from one shared manifold base.
Five swing clamps on a bracket-welding fixture are held by spring force and released by 12 V coil pulses, with flying leads wired straight into the fixture junction box.
On a compact water-treatment skid, the 3/2 stations pilot larger diaphragm process valves, switching each between feed and vent states on demand.
Size the 3V106FI5F both ways. Upward: if any line needs more flow than this smallest 3V body can pass - no Cv is published for 3V1 - move to 3V2, which covers 1/8in and 1/4in with selectable NC or NO function, Cv 0.18-0.19 and a vacuum rating, or to the 1/4in 3V3 at Cv 0.62. On density: 3V2M packs valves even tighter when manifold space, not flow, is the constraint.
Confirm five things with us: M5 versus 1/8in port, PT (standard) or G/NPT thread, the coil voltage for your control circuit, DIN plug versus flying-lead entry, and whether this 5-station assembly or a different count is right. Double-acting actuators belong on the 4V series, not here.
Confirm before you order
Pressure range 0-0.8 MPa (0-114 psi); temperature -20 to 70 C; coil power AC220V 4.5 VA, AC110V 4.5 VA, AC24V 5.0 VA, DC24V 3.0 W, DC12V 2.5 W (fitted here: DC12V at 2.5 W per station); IP65 to DIN 40050; medium is air filtered to 40 um or better, no lubrication needed. AirTAC publishes no Cv or effective-area figure for the 3V1, so treat flow-critical sizing as an item to confirm with us.
The I in 3V106FI5F means each coil is supplied pre-wired with a lead-out instead of a DIN socket, which suits low-voltage panels, battery supplies and vehicles where a 12 V rail already exists. At 2.5 W per station the draw is minimal. If your control system prefers 220 V or 24 V plug-in coils, ask us for the equivalent DIN-entry codes.