The AirTAC Airtac 3V1 Solenoid Valve 3V1M5B15F is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The AirTAC 3V1M5B15F packs fifteen 3/2 solenoid valves onto a single M5 base. Each valve either feeds its outlet or vents it to exhaust, which is exactly what a spring-return cylinder, a blow nozzle or a pilot stage needs. The valve is direct-acting with a single solenoid and spring return, so it shifts regardless of differential pressure.
Every coil draws 3.0 W on DC24V, so the complete 15-station block pulls about 45 W - light enough for a compact control cabinet power supply. The housing is sealed to IP65 (DIN 40050), and each valve carries a manual override for installation and commissioning.
| Model | Airtac 3V1 Solenoid Valve 3V1M5B15F |
|---|---|
| Series | 3V1 |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Port size | M5 |
| Thread | PT |
| Coil voltage | DC24V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 3.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Not published for 3V1 |
| Temperature | -20 to 70 C |
| Construction | Direct-acting, single solenoid, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V1 | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC24V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 15F | 15 stations in one assembly. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Fifteen valves, one per lane, each firing a short pulse of shop air to strip rinse droplets from pharmaceutical vials before inspection.
Spring-return single-acting clamp cylinders hold circuit boards down during electrical test; the block sits directly beside the fixture.
Directs a pressurized rinse line between the sampling needle and waste on a laboratory autosampler, one valve per sample channel.
3V1 is the smallest, lowest-power body in AirTAC's 3V range, and it has no published Cv, so confirm flow-critical duties with us before ordering. If a circuit needs more flow, step up to 3V2 (1/8 and 1/4 ports, NC or NO selectable, Cv 0.18-0.19, vacuum rated) or to 3V3 (1/4 port, Cv 0.62); where manifold density beats raw flow, 3V2M is the alternative body to compare. To drive a double-acting cylinder you need the 5-port AirTAC 4V series instead.
Match five points before you buy: the M5 port (no thread suffix applies at this size), the DC24V coil, DIN plug electrical entry, the 15-station count of this assembly, and an operating pressure window of 0-0.8 MPa against your circuit.
Confirm before you order
Operating pressure 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C, protection IP65 to DIN 40050. Coil power across the range: 4.5 VA on AC220V or AC110V, 5.0 VA on AC24V, 3.0 W on DC24V, 2.5 W on DC12V - this model carries the DC24V coil. AirTAC publishes no Cv or effective area for the 3V1, so confirm any flow-critical duty with us first.
No. A 3/2 valve has one outlet that is either fed or exhausted, so it suits single-acting spring-return cylinders, air blow, clamping and pilot duty. Double-acting cylinders need two working lines - specify the AirTAC 4V series for those. Each of the fifteen valves has a manual override for setup without power.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.