verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 3V1 · 3/2-Way Solenoid Valve

Airtac 3V1 Solenoid Valve 3V1M5BI2F

The AirTAC Airtac 3V1 Solenoid Valve 3V1M5BI2F is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Port sizeM5
  • Coil voltageDC24V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations2
  • Series3V1
$44.55 $49.34Save 9% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V1 Solenoid Valve 3V1M5BI2F

The 3V1M5BI2F ganges two M5-ported 3/2 valves on one common base, each with its own DC24V flying-lead coil. Every valve is direct acting and spring return: energise to feed the outlet, de-energise to vent it, so each station independently controls a single-acting actuator, an air blast or a pilot line.

With both valves sharing one base, plumbing drops to a single supply connection for the pair, and the pre-wired flying leads keep the panel free of connector blocks. Each DC24V coil draws only 3.0 W, so a standard 24 V DIN-rail supply carries the assembly with ease.

Airtac 3V1 Solenoid Valve 3V1M5BI2F Technical Specifications

ModelAirtac 3V1 Solenoid Valve 3V1M5BI2F
Series3V1
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Port sizeM5
ThreadPT
Coil voltageDC24V
Electrical entryFlying lead (lead-out wire type)
Coil power3.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientNot published for 3V1
Temperature-20 to 70 C
ConstructionDirect-acting, single solenoid, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V1 catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

3V1 has no published flow coefficient. There is no Cv and no effective-area figure for this body in the source, so we do not print one. If the duty is flow-critical, ask us and we will confirm it, or step up to 3V2 (Cv 0.18-0.19) or 3V3 (Cv 0.62).

Model Code: Airtac 3V1 Solenoid Valve 3V1M5BI2F

3V1Body — sets the flow, the coil power and whether vacuum is rated.
M5Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
DC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
2F2 stations in one assembly.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V1 Solenoid Valve 3V1M5BI2F Is Used

precision_manufacturing

Spring-return slide on a small press

Each station commands its own function on the press - one drives the single-acting slide forward, the other fires the ejection pin that clears the finished part.

build

Gripper jaws and part-blow jet on a delta pick-and-place robot

Two M5 stations mount side by side to open the gripper and puff the part clear of the tooling, both spring-return so the load drops safely on power loss.

science

Sequenced purge on a bench-top test rig

Bench rigs use paired valves to alternately pressurise and bleed a small chamber between cycles, with flying leads wired straight into a 24 V control rail.

Is the Airtac 3V1 Solenoid Valve 3V1M5BI2F the Right Part?

Size this 2-station assembly by flow first. The 3V1 body is the lowest-flow member of AirTAC's 3V family and its Cv is not published, so treat flow-critical jobs with care: step up to a 3V2 (1/8 or 1/4 port, NC/NO selectable, Cv 0.18-0.19, vacuum rated) or a 3V3 (1/4 port, Cv 0.62) when ports must pass more air, and pick 3V2M where manifold density outranks flow. A 3/2 valve will never stroke a double-acting cylinder - that is a job for the 4V series.

This code already answers most of the five-point check: M5 port, DC24V, flying lead, 2-station manifold. Still confirm the port size (M5 vs 1/8), the thread style on 1/8 codes (PT standard, G or NPT to order) and, if your machine grows, the 1F-20F station range of the family.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V1 Solenoid Valve 3V1M5BI2F FAQ

Pressure range 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, IP65 protection (DIN 40050), and a DC24V coil at 3.0 W per station - 6.0 W for the pair. Air is assumed filtered to 40 um or finer. Note that AirTAC states no Cv for the 3V1 body.

The I in the code means lead-out wires: each coil's connections are pre-wired, so you land them on terminals or a PLC card directly. A DIN-plug version (no I) lets you unplug the connector for fast coil swaps instead - choose per your maintenance strategy.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V1 Solenoid Valve 3V1M5BI2F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V1M5BI2F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.