The AirTAC Airtac 3V100 Solenoid Valve 3V110M5NOFI is a genuine 3-port 2-position (3/2) solenoid valve with M5 ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
The AirTAC 3V110M5NOFI is a genuine 3-port, 2-position (3/2) solenoid valve in the normally open configuration. A 3/2 valve has three ports - supply, outlet and exhaust - and two states: it either feeds the outlet or vents it to exhaust. Because this version is NO, air passes to the outlet whenever the coil is de-energised, and the outlet vents once the coil is energised. The M5 thread is the smallest port in this family, so it pairs naturally with compact single-acting cylinders, small jets and pilot lines. The DC12V coil suits a low-voltage control panel, and the flying-lead entry (suffix I) arrives pre-wired, so no separate DIN socket has to be bought and wired.
This is a genuine AirTAC part. Around it, the 3V1 family offers the other rest state (NC), five coil voltages (AC220V, DC24V, AC110V, AC24V, DC12V), DIN plug or flying-lead entry, and manifold bases for multi-valve installations. Pressure, flow and coil power are not figures we publish for this family; attach a datasheet request to your RFQ and our engineers will confirm them for you.
| Model | Airtac 3V100 Solenoid Valve 3V110M5NOFI |
|---|---|
| Series | 3V110 |
| Valve type | 3/2-way (3-port, 2-position) |
| Initial state | Normally open |
| Port size | M5 |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V110 | Body. |
|---|---|
| M5 | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
On an electronics cleaning bench, the air jet sweeps swarf from PCB trays whenever the 12V control circuit is off, because the normally open valve passes air at rest.
A university materials lab indexes samples with a small spring-return pusher cylinder fed through an M5 port, driven straight from a DC12V bench supply on flying leads.
A small assembly jig clamps a connector housing with a compact spring-return cylinder - a load well matched to the smallest port step and a modest actuator size.
Pick NO when the wanted condition at rest is air at the outlet - a blow-off that must run if power is lost, or a vent that must open on failure. Pick NC when the outlet must stay dead until the coil is energised. The M5 port serves the smallest actuators; for anything bigger, this family steps up through the 1/8in, 1/4in and 3/8in ports, all on PT thread as standard with G and NPT orderable as options. The 12V DC coil has to match your panel supply exactly - a coil cannot be rewired to another voltage. A 3/2 valve drives single-acting (spring-return) loads only; a double-acting cylinder needs a 5-port valve such as the AirTAC 4V series. Because published flow figures for this family are not in our hands, ask us to check sizing against your actuator before ordering - and if you want a 3-port valve with figures in print today, the AirTAC 3V2 and 3V3 bodies carry documented flow and coil-power data.
Confirm before you order
None for this family - we hold no pressure, flow or coil-power data for the 3V1 bodies, so we confirm those from the datasheet when you send an RFQ. If you need published figures straight away, the AirTAC 3V2 (1/8in and 1/4in) and 3V3 (1/4in) valves carry documented flow and coil-power data.
Single-acting spring-return cylinders, air jets and pilot signals - it feeds the outlet at rest and vents it when energised. It cannot drive a double-acting cylinder, which needs a 5-port AirTAC 4V valve instead. For several valves on one shared air feed, look at the 3V100M manifold bases.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.