The AirTAC AirTAC 3V220-06 Solenoid Valve, 3V200 Series (3V22006F) is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.
The AirTAC 3V22006F is a 3-port, 2-position (3/2) solenoid valve in the 3V220 body with a 1/8in PT port and a DC12V coil. A 3/2 valve has three ports - supply, outlet and exhaust - and two states: it either feeds air to the outlet or dumps the outlet to exhaust. That makes it the natural switch for single-acting, spring-return cylinders and simple on/off air tasks. The 12V DC coil suits low-voltage control panels, battery-fed cabinets and mobile equipment where mains control is not on hand.
This is a genuine AirTAC part. Across the 3V1 / 3V2 / 3V3 family you can order either normally closed or normally open behaviour, five coil voltages (AC220V, DC24V, AC110V, AC24V, DC12V), DIN plug or flying-lead entries, and 3V-F manifold bases that carry several valves on one shared supply. Pressure, flow and coil-power figures are not published on this page; send the RFQ and our engineers will read them off the datasheet for you.
| Model | AirTAC 3V220-06 Solenoid Valve, 3V200 Series (3V22006F) |
|---|---|
| Series | 3V220 |
| Valve type | 3/2-way (3-port, 2-position) |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | Confirm from the datasheet — ask us |
| Operating pressure | Confirm from the datasheet — ask us |
| Flow coefficient | Confirm from the datasheet — ask us |
| Temperature | Confirm from the datasheet — ask us |
| Protection | Confirm from the datasheet — ask us |
| 3V220 | Body. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Switches air to a single-acting spring-return clamp on a drill jig: the clamp grips the workpiece for the cut and vents to exhaust when the cycle ends.
Gives a machine operator a solenoid-switched air jet to clear chips and swarf off a freshly milled part before it goes to inspection.
Feeds or vents the pilot port of a larger air-operated process valve on a water-treatment or process skid.
The decodable choices on this SKU are the 1/8in PT port and the DC12V coil with a DIN plug entry. The coil voltage must match the control supply - a solenoid cannot be rewired from one voltage to another - so confirm your panel runs 12V DC before ordering. The 1/8in port is a compact step and suits small single-acting cylinders and light blow-off work; step up to 1/4in or 3/8in for a bigger actuator. PT is the standard thread on this family, with G and NPT available as catalogue options. We hold no published flow figures for the 3V220 body, so ask us to check the valve against your actuator before you commit. For a 3-port valve with published flow and coil-power data today, see the documented 3V2 (1/8in and 1/4in) or 3V3 (1/4in) bodies; for a double-acting cylinder, the 5-port AirTAC 4V series is the answer.
Confirm before you order
We do not publish performance figures for this 3V220 body. Send the RFQ and we will confirm the datasheet pressure range, flow and coil draw for you. If you need published numbers in front of you right now, the 3V2 (1/8in and 1/4in) and 3V3 (1/4in) series carry documented flow and coil-power figures.
No. A 3/2 valve has a single outlet, so it can only feed and vent a single-acting, spring-return actuator, or handle blow-off, clamping and pilot duties. A double-acting cylinder needs a 5-port valve; use the AirTAC 4V series.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.