The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCCI-4F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Four NC valve stations share one supply and one wiring loom on the 3V2MNCCI-4F. Each 3/2 body is direct-acting, single-solenoid, spring return, with coaxial poppet sealing, and every coil is AC110V at 7 VA - a worst case with all four energised is 28 VA, worth checking against your transformer rating. NC logic means an outlet passes no air until energised, the safe default for clamps that should release deliberately.
Centralised exhaust on this base routes all four stations through one common port, so a single silencer and one routed hose keep the manifold area clean. Flying leads simplify hookup, the IP65 coil housings resist dust and splash, and a manual override on each body makes commissioning straightforward. Thread is PT1/8.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCCI-4F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 4 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 4F | 4 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Four spring-return pushers square a layer of cartons on a palletising head, each driven by its own NC manifold station that vents the moment the line stops.
A climate chamber vents its door-seal cylinder and purge jet through two NC stations while two more handle a sample-latch circuit, all on one shared supply.
A powder-coating line sequences hopper valve pilots and feed gates from four NC stations, with the common exhaust routed to a remote silencer.
Decide the five order points first: NC initial state (not convertible later - the dedicated base gasket does not flip the function, so never plan a field change), AC110V coil, flying-lead entry, 4 stations, and centralised exhaust. PT is the standard thread on 3V2M; G and NPT are order options.
Cv 0.1 per station reflects the flow path through the base - manifold density costs flow compared with an individual 3V2 at Cv 0.18 (1/8 in) or 0.19 (1/4 in), which is also vacuum-rated. For the highest flow in the 3V range, 3V3 offers Cv 0.62 at 1/4 in, also vacuum-rated; for the lowest coil power, 3V1 needs only 3.0 W on DC. Double-acting cylinders call for the AirTAC 4V series instead. Genuine AirTAC construction; quote available on request.
Confirm before you order
Flow coefficient Cv 0.1 per station; operating pressure 0-0.8 MPa; temperature range -20 to 70 C; AC110V coil power 7 VA each (28 VA if all four run together); IP65 to DIN 40050; PT1/8 ports; centralised exhaust.
This 4F base vents all stations through one common port, which means simpler piping and a single silencer. If a process must not vent into a shared line - hot, dusty or hygienic zones - order the independent-exhaust variant 3V2MNCCI-4FD, where each station has its own exhaust. Station count is fixed by the base, so choose it for the circuits you need now, plus one spare if expansion is likely.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.