verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNCCI-4F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCCI-4F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally closed
  • Port size1/8 in
  • Coil voltageAC110V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations4
  • Flow (Cv)0.1
  • Series3V2M
$170.76 $178.68Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNCCI-4F

Four NC valve stations share one supply and one wiring loom on the 3V2MNCCI-4F. Each 3/2 body is direct-acting, single-solenoid, spring return, with coaxial poppet sealing, and every coil is AC110V at 7 VA - a worst case with all four energised is 28 VA, worth checking against your transformer rating. NC logic means an outlet passes no air until energised, the safe default for clamps that should release deliberately.

Centralised exhaust on this base routes all four stations through one common port, so a single silencer and one routed hose keep the manifold area clean. Flying leads simplify hookup, the IP65 coil housings resist dust and splash, and a manual override on each body makes commissioning straightforward. Thread is PT1/8.

Airtac 3V2M Solenoid Valve 3V2MNCCI-4F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNCCI-4F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally closed
Item formComplete assembly — 4 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC110V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNCCI-4F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NCNormally closed: no air at the outlet until the coil is energised.
AC110VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
4F4 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNCCI-4F Is Used

local_shipping

Palletiser pusher row

Four spring-return pushers square a layer of cartons on a palletising head, each driven by its own NC manifold station that vents the moment the line stops.

science

Environmental chamber door

A climate chamber vents its door-seal cylinder and purge jet through two NC stations while two more handle a sample-latch circuit, all on one shared supply.

tune

Coating line feed gate

A powder-coating line sequences hopper valve pilots and feed gates from four NC stations, with the common exhaust routed to a remote silencer.

Is the Airtac 3V2M Solenoid Valve 3V2MNCCI-4F the Right Part?

Decide the five order points first: NC initial state (not convertible later - the dedicated base gasket does not flip the function, so never plan a field change), AC110V coil, flying-lead entry, 4 stations, and centralised exhaust. PT is the standard thread on 3V2M; G and NPT are order options.

Cv 0.1 per station reflects the flow path through the base - manifold density costs flow compared with an individual 3V2 at Cv 0.18 (1/8 in) or 0.19 (1/4 in), which is also vacuum-rated. For the highest flow in the 3V range, 3V3 offers Cv 0.62 at 1/4 in, also vacuum-rated; for the lowest coil power, 3V1 needs only 3.0 W on DC. Double-acting cylinders call for the AirTAC 4V series instead. Genuine AirTAC construction; quote available on request.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNCCI-4F FAQ

Flow coefficient Cv 0.1 per station; operating pressure 0-0.8 MPa; temperature range -20 to 70 C; AC110V coil power 7 VA each (28 VA if all four run together); IP65 to DIN 40050; PT1/8 ports; centralised exhaust.

This 4F base vents all stations through one common port, which means simpler piping and a single silencer. If a process must not vent into a shared line - hot, dusty or hygienic zones - order the independent-exhaust variant 3V2MNCCI-4FD, where each station has its own exhaust. Station count is fixed by the base, so choose it for the circuits you need now, plus one spare if expansion is likely.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNCCI-4F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNCCI-4F and will confirm price, stock and lead time — usually within 7-8 hours.