The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCF-13F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
The 3V2MNCF-13F packs thirteen normally closed 3/2 valves onto one AirTAC base, all direct-acting, single-solenoid and spring return, with a coaxial shut-off poppet that seals well cycle after cycle. Ports are PT1/8 and the flow coefficient per station is Cv 0.1. Nothing moves to the outlet until the relevant 12 V coil is energised.
Thirteen separately plumbed valves can be slow to troubleshoot; here, one shared supply and one wiring run mean a dead circuit is traced station by station in minutes, and different valve types can sit side by side on the same manifold. Budget 13 x 7.0 W = 91 W for a fully energised bank, about 7.6 A at 12 V. The exhaust is centralised, leaving through a common base port.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCF-13F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 13 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 13F | 13 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Thirteen spring-return clamps grip fill heads on a rotary bottler; each NC station vents to the safe open state the moment its coil drops out.
A metrology bench uses isolated 3/2 channels to switch pilot air to one gauge circuit at a time without cross-bleeding between stations.
Normally closed valves hold interlock latches released only while powered, so a control failure leaves every door free to return to its safe state.
This code fixes five choices for you: NC state, DC12V coils, DIN plug entry, a 13-station base and centralised exhaust. Thread is PT by default, with G and NPT available to order.
If any single station needs more than Cv 0.1, mount an individual 3V2 beside the bank (Cv 0.18 at 1/8 inch, 0.19 at 1/4 inch, and vacuum-rated) or a 3V3 at Cv 0.62 for the highest flow in the range. Small duties can drop to 3V1 at 3.0 W DC. Remember the NC/NO state is permanent once purchased, and double-acting cylinders call for the AirTAC 4V series.
Confirm before you order
Thirteen NC 3/2 stations, Cv 0.1 per station, 0-0.8 MPa operating pressure, -20 to 70 C temperature, 7.0 W per DC12V coil (91 W all on), IP65 protection, PT1/8 ports, spring return, direct-acting coaxial poppet construction, 40 um maximum air filtration.
This assembly vents all thirteen stations through one common base port, which keeps tubing short and silencing simple. Choose the D (independent exhaust) variant instead when a station must not see back-pressure from others, for example where exhaust speed affects cylinder return time.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.