The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCF-16F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Sixteen normally closed 3V2M valve bodies on a single dedicated base: that is the 3V2MNCF-16F. Every body is a direct-acting 3/2 unit with one DC12V solenoid and spring return, coaxial poppet sealing, and no air at its outlet until the coil is energised.
Size the 12 V supply for the worst case, not the average. Each DC coil draws 7.0 W, so sixteen stations energised together need about 112 W, roughly 9.3 A at 12 V - before any other load on the rail. Exhaust on this assembly is centralised, so all sixteen valves vent through the shared base port; keep that path free of back pressure. The IP65 (DIN 40050) coil housings and fitted manual override make panel installation and commissioning straightforward.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCF-16F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 16 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 16F | 16 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Sixteen spring-return swing clamps on a modular welding fixture plate, one NC valve per clamp so each point is fed or vented independently from a single manifold.
A bank of small pneumatic presses driving spring-return punches for rivet and fastener setting, with shared wiring making station-level fault finding quick.
A wire-harness forming board where sixteen NC valves actuate hold-down pins along the rail, releasing every point at once when the line stops.
At Cv 0.1 per valve, the 3V2M family buys manifold density at the cost of per-station flow. A station that needs more can take an individual 3V2 body (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, and vacuum-rated), while 3V3 reaches Cv 0.62 on 1/4 in ports, and 3V1 suits small duties at just 3.0 W DC. A double-acting cylinder cannot be driven by a 3-port valve - send that requirement to the AirTAC 4V series.
Confirm five things when ordering: NC initial state (not convertible after purchase), DC12V coil, DIN plug entry, 16 stations and centralised exhaust, plus thread - PT is the standard on this family, with G and NPT as order options.
Confirm before you order
Each DC12V coil draws 7.0 W, so a fully energised 16-station assembly needs about 112 W, roughly 9.3 A at 12 V. Other ratings: Cv 0.1 per valve, pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, IP65 (DIN 40050).
On the -16F all sixteen valves vent through one shared port on the base, which keeps plumbing simple but means every station shares that path. If a circuit needs each valve to vent separately, order the D version with independent exhaust instead. Exhaust style, like state and voltage, is fixed by the code you order.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.