
The AirTAC Airtac 3V2M Solenoid Valve 3V2MNCFI-19F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Nineteen switching points in a single manifold row is what the 3V2MNCFI-19F is built for. Every station is a normally closed, direct-acting 3/2 poppet valve with spring return, fitted with a DC12V coil of 7.0 W on flying leads. The bodies share one supply gallery and one wiring harness through the 3V2M base, which is why commissioning a 19-station machine goes faster than chasing nineteen individual body-mounted valves.
That density has a price in flow: because the air path runs through the base, each station is Cv 0.1, below the individually-ported 3V2 at Cv 0.18. For grippers, pilot lines and small clamps that is ample; for a fast-cycling large bore, plan a mixed build instead. IP65 coil protection, a manual override on each body and PT1/8 ports as standard round out the package, with the whole bank venting through one centralised exhaust path.
| Model | Airtac 3V2M Solenoid Valve 3V2MNCFI-19F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally closed |
| Item form | Complete assembly — 19 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NC | Normally closed: no air at the outlet until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 19F | 19 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Nineteen clamping and purge ports on a PCB or module test fixture are switched station by station, with the manifold keeping the fixture's air drop and control harness down to one of each.
Each spring-return actuator position in a laboratory sample handler gets its own NC station, so a vial is clamped only while the sequencer holds that output energised.
Pilot and positioner signals on a water-treatment skid are switched from one manifold row; at Cv 0.1 the stations are sized for pilot lines rather than large power cylinders.
Work through the five matching points: normally closed initial state, DC12V voltage, flying-lead entry, 19 stations, centralised exhaust - and PT thread as shipped standard, with G or NPT as catalogue options to order. Bear in mind that NC and NO cannot be interchanged after purchase; the base gasket on 3V2M is dedicated and reversing it changes nothing.
If a station turns out to need more passage than Cv 0.1 allows, step that position up: a single 3V2 gives Cv 0.18 at 1/8 or 0.19 at 1/4 and carries a vacuum rating, 3V3 offers Cv 0.62 at 1/4 for the highest flow in the 3V family, and 3V1 draws only 3.0 W on DC for modest duties. A double-acting cylinder is outside what any 3-port valve can drive - specify the AirTAC 4V 5-port series for that.
Confirm before you order
Per station: 3/2 direct-acting poppet function, flow coefficient Cv 0.1, pressure range 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, DC12V coil at 7.0 W, IP65 (DIN 40050) protection, PT1/8 ports. The medium is air filtered to 40 um or finer and the valve runs dry - no lubricator needed.
Decide from the machine logic: normally closed passes no air at the outlet until energised, normally open does the opposite. Once ordered the state cannot be changed in the field - flipping or reversing the dedicated base gasket does not convert NC to NO on 3V2M. If any single station needs a larger bore or vacuum service later, that position can be re-planned around an individual 3V2 or 3V3 instead.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.