verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOAI-8F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOAI-8F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageAC220V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations8
  • Flow (Cv)0.1
  • Series3V2M
$331.48 $343.39Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOAI-8F

The 3V2MNOAI-8F arrives as a complete eight-station block: eight 3/2 normally open valve bodies pre-mounted on a dedicated 8F base, wired with flying leads and fed from a single AC220V supply. Every valve is normally open, so compressed air flows to each outlet until its solenoid is energised - useful where a machine must pass air at rest, for example venting or blowing between cycles.

Each valve is direct-acting with a spring return and a coaxial poppet shut-off, rated Cv 0.1 and IP65 (DIN 40050). Because all eight bodies sit on one base, they share one air supply and one wiring harness, so a fault on any station is found faster than tracing eight separate valves.

Airtac 3V2M Solenoid Valve 3V2MNOAI-8F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOAI-8F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 8 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageAC220V
Electrical entryFlying lead (lead-out wire type)
Coil power7 VA
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOAI-8F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
AC220VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
8F8 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOAI-8F Is Used

packaging

Packaging line hold-down clamp array

Eight NO valves keep spring-return clamps pressurised between cycles on a carton sealing machine, dropping each clamp only when the PLC energises that station during pallet ejection.

conveyor_belt

Conveyor divert air-jet bank

A row of blow nozzles above a belt sorter stays on at rest; each NO station cuts its jet only when energised, letting the shared AC220V supply feed all eight from one manifold.

factory

Paint booth purge manifolds

Continuous purge air to booth nozzles runs through eight normally open ports, with one energised shut-off per zone for maintenance without disturbing the other seven.

Is the Airtac 3V2M Solenoid Valve 3V2MNOAI-8F the Right Part?

Confirm the initial state before ordering: NO here means air passes until energised, and this cannot be converted afterwards - the dedicated base gasket cannot be flipped to change NC to NO or the reverse. If a station needs more flow than Cv 0.1, move that circuit to an individual 3V2 (Cv 0.18 at 1/8 inch, 0.19 at 1/4 inch, vacuum-rated) or to 3V3 (Cv 0.62, 1/4 inch). For small duties, 3V1 draws only 3.0 W on DC.

Match five points: initial state (NO), coil voltage (AC220V here), electrical entry (flying lead, not a DIN socket), station count (8F), and exhaust (centralised, all stations vent through one port). PT thread is standard on this family; G and NPT are catalogue options to order. For a double-acting cylinder you need a 5-port AirTAC 4V valve, not this 3/2 series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOAI-8F FAQ

Eight normally open 3/2 valves, AC220V coils at 7 VA each, flying-lead entry, Cv 0.1 per valve, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, IP65 (DIN 40050), PT1/8 ports on a centralised-exhaust 8F base. Full datasheet available on RFQ.

The I entry replaces each DIN socket with a pre-wired lead-out, so the eight stations land on terminal strips without ordering separate plugs - handy in a controlled AC220V panel. If your panel prefers plug-in coils, order the non-I version with DIN sockets instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOAI-8F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOAI-8F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.