The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOC-7F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Seven stations on one PT1/8 block: 3V2MNOC-7F packs seven normally open 3/2 poppet valves where seven individual valves would need seven separate fittings and harnesses. The trade-off is flow - Cv 0.1 per valve, because air routes through the base rather than straight into each port.
The normally open behaviour suits circuits that must pass air while de-energised, such as vent-safe clamping or fail-to-position blow lines. Seven AC110V coils add 49 VA of holding load; each is IP65 rated, and the coaxial shut-off, spring-return poppet is direct-acting with a manual override. Order the state deliberately - it is fixed at the factory by the dedicated base gasket.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOC-7F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 7 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | AC110V |
|---|---|
| Electrical entry | DIN plug (DIN socket type) |
| Coil power | 7 VA |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| AC110V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| — | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 7F | 7 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Seven small workholders on an SMT support bench each get one manifold station, keeping a single air drop and one harness instead of a valve-and-fitting cluster.
A laboratory vial filler drives seven stopper presses from the 7-station base; Cv 0.1 per valve suits the small bore of each press cylinder.
Seven toggle clamps on a cabinet jig hold panels while glued; each normally open station keeps its clamp charged and vents on command to release.
Size by duty, not by station count: at Cv 0.1 each of the seven valves comfortably handles small single-acting cylinders, clamps and pilot lines. Add an individual 3V2 (Cv 0.18 at 1/8, 0.19 at 1/4, vacuum-rated) or 3V3 (Cv 0.62, vacuum-rated) for any port that needs more flow; 3V1 saves power at 3.0 W DC. For double-acting cylinders, move to the 5-port AirTAC 4V series.
Lock in the five order points before buying: NO state, AC110V, DIN plug entry, 7 stations, centralised exhaust, PT thread as standard (G/NPT to order). Neither the state nor the gasket can be altered in the field to change it.
Confirm before you order
Each 3/2 valve: direct-acting poppet, Cv 0.1, 0-0.8 MPa (0-114 psi), -20 to 70 C media, IP65 (DIN 40050) housing, AC coil 7 VA (DC 7.0 W), manual override fitted. Base: 7F block, PT1/8, centralised exhaust, one shared supply. Air must be filtered to 40 um or finer; lubrication is not required.
In this 7F set all seven stations vent through one shared exhaust path, so one silencer and one pipe serve the whole manifold - tidy and economical. If a station must vent to a separate point (confined space, captured fumes), order the -D independent-exhaust variant instead.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.