2、Coaxial shut-off design ensures excellent sealing performance and high flow capacity; Requires no oil lubrication;
3、Equipped with manual override for simplified installation and commissioning;
4、Modular design with base mount enables multi-valve integration for space-saving configurations;
5、Centralized air supply and integrated wiring streamline troubleshooting during fault diagnosis;
6、Flexible and scalable configuration supports arbitrary combinations or expansion of valve quantities/types;
7、Dedicated base gasket design – Flipping the gasket does not allow NC/NO conversion.
Category: Solenoid Valves , Brand: AirTAC , Series: 3V2M
AirTAC 3V2MNOF-5F Solenoid Valve Specifications
- Model: 3V2MNOF-5F
- Type: 3/2-way normally open (direct-acting)
- Port size: PT1/8 (G1/8 optional with adapter)
- Thread standard: ISO228/ISO6149 compliant
- Operating pressure: 0.15–0.8 MPa (21.7–116 PSI)
- Max flow rate: 750 L/min (Cv=1.2 at 0.5 MPa)
- Voltage options: DC12V (±10%), DC24V (±10%), AC110V (50/60Hz), AC220V (50/60Hz)
- Response time: ≤15ms (energize), ≤20ms (de-energize)
- Weight: 185g ±5g (with connector)
- Dimensions: 52mm(L) × 38mm(W) × 68mm(H)
- Body material: Reinforced PBT with UL94 V-0 rating
- Seal material: FDA-compliant FKM (Viton® equivalent)
- Temperature range: -10℃ to 80℃ (non-freezing conditions)
- Power consumption: 1.6W (DC), 2.3VA (AC)
- Protection rating: IP67 (dustproof/water immersion resistant)
- Cycle life: ≥10 million operations (at max rated conditions)
High-flow solenoid valve with dual-chamber design for stable pressure regulation in high-vibration environments. Features integrated surge protection and reverse polarity safeguard. The corrosion-resistant construction with gold-plated terminals ensures reliable performance in humid conditions. Requires 25μm filtered dry air with ISO8573-1:2010 Class 4.4.3 air quality.
- Industrial automation: CNC machine tool changers
- Packaging lines: Bottle capping/carton sealing systems
- Food processing: Pneumatic control for filling machines
- Semiconductor manufacturing: Cleanroom actuator control
- Railway systems: Door control mechanisms
1. Mount in horizontal orientation only (coil axis vertical)
2. Use vibration-damping brackets if ambient vibration exceeds 5G
3. For AC models: Install surge absorber when switching inductive loads
4. Lubricate with ISO VG32 turbine oil if used in continuous operation >12hrs/day
- Manifold base: MPA-L04 (4-station) / MPA-L08 (8-station)
- Quick-connect kit: QCK-3V2M (includes DIN43650 connector)
- Optional silencer: SRN-05 (noise reduction ≤68dB(A))
| Property | Property Value |
|---|---|
| sku | 3V2MNOF-5F |
| Position | 3-Port 2-Position |
| Initial Position | Normally Open |
| Standard Voltage | DC12V |
Returns will be accepted for up to 15 days of Customer’s receipt or tracking number on Not used items. You, as a Customer, are obliged to inform us via email before you return the item, only in the case of:
- Received the wrong item.
- Item arrived not as expected (ie. damaged packaging).
- Item had defects.
- Over delivery time.
- The shipper does not allow the goods to be inspected before payment.
The returned product(s) must be in the original packaging, safety wrapped, undamaged and unworn. This means that the item(s) must be safely packed in a carton box for protection during transport, possibly the same carton used to ship to you as a customer.