verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOFI-5F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOFI-5F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations5
  • Flow (Cv)0.1
  • Series3V2M
$210.97 $219.89Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOFI-5F

Order the 3V2MNOFI-5F and you receive a five-station bank of normally open 3/2 valves already matched to its base and wired with flying leads rather than DIN sockets. The pre-fitted lead-out wire saves plugging five separate connectors during panel assembly and keeps each coil drop tidy inside tight cabinets. Valves are direct-acting, spring return and coaxial poppet sealed; until a coil energises the outlet is fed, and on energising it vents.

Each DC12V coil takes 7.0 W, so five coils at full simultaneous pull-in ask about 35 W - roughly 3 A from the 12 V rail. Protection is IP65 (DIN 40050), flow is Cv 0.1 per station, and a manual override on each valve eases setup. The shared 5F base feeds all stations from one PT1/8 point. This is genuine AirTAC product distributed by AirtacDistr; for anything beyond the published data, raise an RFQ.

Airtac 3V2M Solenoid Valve 3V2MNOFI-5F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOFI-5F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 5 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryFlying lead (lead-out wire type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOFI-5F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
5F5 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOFI-5F Is Used

settings_input_component

Rotary indexing dial

A five-position indexing dial actuates its part clamps and eject stroke from one 3V2M base; the fifth station holds the reject chute, whose NO valve vents the chute cylinder whenever the panel is unpowered.

factory

Bottling line hold-down clamps

Five hold-down clamps on a filling carousel share one PT1/8 supply; each 3/2 station feeds its spring-return clamp cylinder and vents it in the same cycle, so a sticky clamp is traced station by station.

bolt

Automated fastening cell

In a screwdriving cell, the bit-advance and part-clamp cylinders for five spindles each hang off one manifold station, letting a faulty axis be swapped without rewiring the control loom.

Is the Airtac 3V2M Solenoid Valve 3V2MNOFI-5F the Right Part?

The 3V2M family trades flow for density: Cv 0.1 per station through the base, versus Cv 0.18 at 1/8 in on a standalone 3V2 (0.19 at 1/4 in, vacuum-rated) and Cv 0.62 on a 3V3 when a port needs real throughput; pick 3V1 instead if 3.0 W DC suffices on a light load. The normally open state is fixed at order time - flipping the dedicated base gasket will not convert it, and no field method exists - so state NO explicitly. Check each point before checkout: initial state, coil voltage (DC12V), electrical entry (flying lead), station count (5F), exhaust (centralised) and thread (PT is standard; G and NPT are order options). Double-acting cylinders require the 5-port AirTAC 4V series.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOFI-5F FAQ

Five normally open 3/2 valves on one base. Flow coefficient Cv 0.1 per station, pressure range 0-0.8 MPa (0-114 psi), medium temperature -20 to 70 C, each DC12V coil 7.0 W (about 35 W if all five energise at once), IP65 rating to DIN 40050, PT1/8 connections.

Feed-and-vent duties only: single-acting spring-return cylinders, clamps, air blow nozzles and pilot stages. It cannot run a double-acting cylinder - that needs two outlet lines, so specify the 5-port AirTAC 4V series instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOFI-5F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOFI-5F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.