The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOFI-7F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
In the 3V2MNOFI-7F the 7-station base uses centralised exhaust: all seven 3/2 valves vent into one shared port, which keeps the manifold's outer face clean and silencing simple - one muffler serves the group instead of seven loose vents. The valves themselves are normally open, so outlets carry air until each DC12V coil is energised and the spring vents that line. Construction is direct-acting with a coaxial shut-off poppet.
Flow is Cv 0.1 per station at 0-0.8 MPa, with IP65 coils drawing 7.0 W each - about 49 W, near 4 A at 12 V, for a fully energised seven. Wiring converges on one shared point of the base, which shortens fault-finding to coil-by-coil checks. Should a station later need to vent separately, that is the D (independent exhaust) version of the same family. Genuine AirTAC valves and base; PT thread standard.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOFI-7F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 7 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 7F | 7 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
A pick panel with seven spring-return grippers assigns one 3V2M station per gripper; adding an eighth gripper means adding a valve and base station, not redesigning the manifold.
A sorting hub runs seven diverter arms along the sorter, each needing one 3/2 signal valve; centralised exhaust lets the frame carry a single muffler rather than seven loose vents.
On a furnace-door interlock panel, seven NO valves hold vent paths open so doors cannot remain clamped if the 12 V control circuit fails.
This assembly wins on count, not on flow: Cv 0.1 per station through the shared base, so step to a standalone 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in, vacuum-rated) wherever one output needs more air; drop to 3V1 at 3.0 W DC for light duty. Confirm the order code before checkout: initial state NO, coil DC12V, flying-lead entry, 7 stations, centralised exhaust, PT thread standard with G or NPT to order. The state is permanent - a normally open 3/2M cannot be turned normally closed after purchase by any means, including the base gasket, which is not reversible. Double-acting cylinders need an AirTAC 4V 5-port valve.
Confirm before you order
Seven NO 3/2 valves on a 7F base: Cv 0.1 per station, 0-0.8 MPa (0-114 psi), -20 to 70 C, DC12V coil 7.0 W each (about 49 W, near 4 A at 12 V, all energised), IP65 to DIN 40050, PT1/8 threads.
Decide by fail state: NO keeps the outlet fed when power drops, NC shuts it. A 3V2M cannot be converted later - the dedicated base gasket does not reverse the state - so the initial state must be right when ordering. This 7F assembly is NO; for closed-at-rest duties order the NC version of the same code.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.