verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V320 · 3/2-Way Solenoid Valve

AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E)

The AirTAC AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E) is a genuine 3-port 2-position (3/2) solenoid valve with 3/8 in ports. A 3/2 valve either feeds its outlet or vents it to exhaust, so it suits single-acting cylinders, air blow, clamping, vacuum switching and pilot duty. We stock this code and confirm its published figures from the datasheet on request.

  • Valve type3/2-way (3-port, 2-position)
  • Port size3/8 in
  • Coil voltageAC24V
  • Electrical entryDIN plug (DIN socket type)
  • Series3V320
$60.43 $65.62Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V320-10 valve type, voltage, entry and pilot on one page All 3V320-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E)

A genuine AirTAC 3/2 solenoid valve, the 3V32010E pairs the largest port in the family, 3/8in, with an AC24V coil. Three ports mean supply, outlet and exhaust; two positions mean the valve either pressurises the outlet or vents it. That on-or-vent behaviour is what a single-acting cylinder, an air-blow nozzle or a pilot line expects. The AC24V coil suits low-voltage control circuits where operators work near the valve, and the DIN plug entry keeps the connection on the body itself. Because the code carries no NC or NO marker, choose the state when you order.

The 3V1 / 3V2 / 3V3 family around this valve also offers the other initial state, AC220V, AC110V, DC24V and DC12V coils, flying-lead wiring and 3V-F manifold bases that carry several valves from one air feed. Nothing on this page quotes performance: put your operating conditions in an RFQ and our engineers will verify the datasheet values against them.

AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E) Technical Specifications

ModelAirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E)
Series3V320
Valve type3/2-way (3-port, 2-position)
Port size3/8 in
ThreadPT
Coil voltageAC24V
Electrical entryDIN plug (DIN socket type)
Coil powerConfirm from the datasheet — ask us
Operating pressureConfirm from the datasheet — ask us
Flow coefficientConfirm from the datasheet — ask us
TemperatureConfirm from the datasheet — ask us
ProtectionConfirm from the datasheet — ask us
We do not publish figures we cannot stand behind. We stock this code and ship it as a genuine AirTAC part, but we do not hold a specification sheet for the 3V320 family. Operating pressure, flow, coil power, protection rating and temperature are therefore not printed here — send us the model and we will confirm them from the factory datasheet, usually within 7-8 hours.

Model Code: AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E)

3V320Body.
3/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
AC24VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
—Electrical entry: I = flying lead, otherwise a DIN plug.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E) Is Used

settings_input_component

Piloting a larger process valve

Sending an air signal from an AC24V control circuit to a bigger pneumatic valve or actuator, with the 3/2 venting the pilot line when the signal must stop.

science

Lab bench actuator switching

Driving a small spring-return test-rig cylinder on a materials bench, where the low-voltage coil sits safely beside the operator and instruments.

tune

Air purge on a printing or converting machine

Feeding a purge nozzle that clears ink mist and paper dust from rollers, venting the line whenever the station is idle.

Is the AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E) the Right Part?

Start with the fail-safe question. A normally closed version leaves the outlet vented whenever power is lost, which is usually what you want on a clamp or a blow point; a normally open version keeps the outlet fed until energised. The 3/8in port accepts fittings for a larger single-acting actuator than the 1/8in or 1/4in sizes. This SKU is wound for AC24V - the coil cannot be converted to another voltage by rewiring, so order the suffix that matches your transformer. If you would rather have pre-attached wires than a DIN socket, ask about the flying-lead entry in this family.

We cannot hand you a flow figure for this series, so let us check the valve against your cylinder before you order. Where published flow and coil power are a must, the 3V2 and 3V3 bodies are the documented AirTAC 3-port alternatives.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Wiring by qualified personnel, per AirTAC documentation.

AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E) FAQ

This page carries no performance figures, so we will pull the pressure range, flow and coil power from the AirTAC datasheet for you - just raise an RFQ. If your process demands numbers you can read yourself right now, look at the AirTAC 3V2 and 3V3 series, whose flow and coil-power figures are published.

Decide what the outlet should do when the power fails. If it must lose air and vent - typical for clamps and blow points - order normally closed. If it must keep feeding, order normally open. The 3V320 is available in both states across the family; this code leaves the state open, so state your preference when you order.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 3V320-10 Solenoid Valve, 3V300 Series (3V32010E)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V32010E and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.