verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI)

The AirTAC AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI) is a genuine 5/2-way single solenoid (spring return) solenoid valve with 11006CI ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port size11006CI
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$25.55 $33.05Save 22% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI)

The AirTAC 4V110-06CI is a 5/2-way single-solenoid directional control valve built on the compact 4V100 body. It directs compressed air to double-acting cylinders and actuators, energizing to shift the spool and returning to its home position via a mechanical spring when the signal is removed. This spring-return action makes it a natural fit for tasks where the actuator must default to a safe, known state on power loss.

This specific configuration ships with an AC110V coil drawing 3.5 VA and uses a grommet-style electrical entry with a 0.5 m pre-wired flying lead for fast DIN-rail wiring. With an effective area of 10.2 mm² (Cv 0.6) and a response time of 0.05 s or less, it reliably cycles small clamps and ejectors on 1/8-inch PT-ported manifolds.

AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI) Technical Specifications

ModelAirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI)
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port size11006CI
Exhaust port11006CI
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight120 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI)

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-11006CIPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI) Is Used

handyman

Small-Bore Clamping Fixtures

Drives a Ø20 mm double-acting clamp cylinder on a benchtop welding jig. The spring return ensures the clamp retracts when the AC110V signal is cut, clearing the part safely.

precision_manufacturing

Pick-and-Place Ejectors

Controls a compact pneumatic ejector on an electronics assembly cell. The 0.05 s response time and grommet wiring suit the high-cycle, space-constrained environment.

science

Laboratory Sampler Actuation

Shifts a small double-acting actuator on a gas chromatograph auto-sampler. The 3.5 VA AC110V coil and pre-wired grommet lead simplify integration into the instrument's control panel.

Is the AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI) the Right Valve?

Choose the 4V110-06CI when your application needs a single electrical signal to drive a double-acting cylinder and you want the spool to spring back deterministically when de-energized. Its Cv of 0.6 suits cylinders in the ~Ø16-32 mm range at typical shop pressures. If your cylinder is larger or you need faster fill rates, step up to a 4V200-series valve (Cv 1.0) to avoid flow starvation.

For replacement, match five points exactly: 4V100 body size, 5/2 single-solenoid function, 1/8-inch port with PT (tapered) thread, AC110V coil voltage, and the grommet (I) entry. This model can be mounted on a manifold base to build a compact valve terminal, or used as a stand-alone unit with individual sub-base piping.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI) FAQ

With an effective area of 10.2 mm² (Cv 0.6), this 4V100-body valve suits double-acting cylinders roughly in the Ø16-32 mm range. It is not a fixed datasheet limit—actual speed depends on your operating pressure, tubing length, and the cylinder's specific bore and stroke. For larger cylinders, moving to a 4V200 series (Cv 1.0) will provide a more responsive cycle.

The 4V110-06CI is a single-solenoid valve. When the AC110V coil is energized, the spool shifts to extend or retract the cylinder. The moment power is removed, the internal spring forces the spool back to its default position. This guarantees the actuator returns to a predetermined state, which is critical for safety and reset operations.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V110-06CI Solenoid Valve, 5/2-way, PT1/8, AC110V, grommet entry (4V11006CI)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V11006CI and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.