verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM)

The AirTAC AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM) is a genuine 5/2-way single solenoid (spring return) solenoid valve with AM ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port sizeAM
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$30.93 $35.38Save 12% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V110-06 stroke, mounting and version on one page All 4V110-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM)

The AirTAC 4V11006FI-AM is the smallest body in the 4V range: a 5/2-way single-solenoid valve that switches a double-acting cylinder between extend and retract, then springs back to its rest position the moment the coil is de-energised, so your control signal must stay on for as long as the working stroke is needed. With an effective area of 10.2 mm2 (Cv 0.6) and a 5 cycle/s ceiling, it is sized for compact double-acting actuators in roughly the 16-32 mm bore class.

This -AM build arrives with an AMISCO (Italian) solenoid coil factory-fitted in place of the standard AirTAC coil; the spool, 1/8in PT ports and flow figures are identical, but our datasheet covers only the standard coil, so please confirm the exact AMISCO rating with us before sizing your DC12V power supply. Wiring is via a grommet entry with a 0.5 m pre-wired lead, switching response is 0.05 s or better, and the aluminium body weighs just 120 g - a neat package where panel space and install time both matter.

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM) Technical Specifications

ModelAirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM)
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port sizeAM
Exhaust portAM
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight120 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM)

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-AMPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM) Is Used

cable

Battery-powered mobile rigs

The DC12V coil runs straight from vehicle and battery supplies, and the grommet's 0.5 m flying lead makes hookup on service carts, small mobile equipment and field prototypes quick and vibration-tolerant.

precision_manufacturing

Benchtop automation cells

Compact indexing slides, pick-and-place fingers and small rotary actuators cycle well within the Cv 0.6 flow class, while the spring return guarantees a defined home position between cycles.

bolt

Compact clamping and gripper circuits

Cutting the signal releases the clamp or gripper automatically on this spring-return 5/2, a useful fail-to-rest behaviour for fixtures on small double-acting clamps in the 16-32 mm range.

Is the AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM) the Right Valve?

Keep the 4V100 body for small bores and moderate cycle rates; step up to the 4V200 (Cv 1.0) when a larger cylinder or faster travel demands it. Pick this single-solenoid 5/2 if a dropped signal should always park the cylinder at rest; choose a double-solenoid 4V120 when position should persist through a power loss, or a 4V130 5/3 (its Cv 0.51 and 3 cycle/s limit make it slower) when you need an intermediate port state. One valve can also sit on a manifold base to grow into a multi-station group. For reorders or swaps, lock in five points: 4V100 body, function 10, 1/8in PT thread, DC12V coil and grommet entry - and if your process depends on the AMISCO coil, make sure that option carries over and that its rating has been confirmed.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM) FAQ

Its 10.2 mm2 effective area (Cv 0.6) and 5 cycle/s maximum suit double-acting cylinders and actuators around the 16-32 mm bore class. It is not a 3/2 valve, so it will not vent a single-acting cylinder - those need a different function.

Because the -AM suffix means an AMISCO (Italian) coil is fitted instead of the standard AirTAC coil, and the published power figures apply only to the standard part. The valve still operates on DC12V; simply confirm the AMISCO coil's exact rating with us before selecting a power supply or fuse.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V110-06 Solenoid Valve, 4V100 Series (4V11006FI-AM)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V11006FI-AM and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.