The AirTAC Airtac 4V100 Solenoid Valve 4V110M5-X0 is a genuine 5/2-way single solenoid (spring return) solenoid valve with X0 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
4V110M5-X0 is the sub-miniature M5-port version of the AirTAC 4V100 spring-return 5/2 valve. One solenoid shifts the spool to pressurise one side of a double-acting actuator and exhaust the other; when the signal is removed, the internal spring snaps the spool back, so holding the extended stroke always requires a live coil signal. Because the port is M5, the code carries no thread letter - the connection is standard M5 male metric, made for direct mounting of miniature fittings.
Internally the valve flows Cv 0.6 through an effective area of 10.2 mm2 and switches in 0.05 s or less from a 0.15-0.8 MPa supply, enough for double-acting cylinders of about Dia16-32 mm bore where panel space, not flow, is the real constraint - the 120 g aluminium body is barely larger than the fittings around it. Coil voltage is not fixed by this code: state AC220V, DC24V, AC110V, AC24V or DC12V when ordering, and specify the entry style at the same time.
| Model | Airtac 4V100 Solenoid Valve 4V110M5-X0 |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | X0 |
| Exhaust port | X0 |
| Effective area (Cv) | 10.2 mm² (Cv 0.6) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 120 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 10.2 mm² |
|---|---|
| Flow coefficient | Cv 0.6 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -X0 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
Two-finger micro grippers on a desktop electronics placement cell take M5 plumbing directly, and the Cv 0.6 flow with a 5 cycles per second ceiling keeps a Dia16-driven gripper (1.0 kgf push at 0.5 MPa) inside a one-part-per-second takt.
On an X-Y dispensing head, the spring-return 5/2 retracts a Dia20 slide (1.6 kgf push at 0.5 MPa) the instant the low-power coil signal is cut, clearing the needle path between dispenses with no latching circuit to wire.
A Dia25 reject finger (2.45 kgf at 0.5 MPa) flicks failed components off the inspection track; the 0.05 s response keeps the reject window narrow at line speed while the M5 ports fit inside the module housing.
Work downwards and upwards before you commit. Nothing in the 4V100 range goes below M5, so the only step down is a different, smaller series; the immediate step up is the 4V110-06 with 1/8in ports at the same Cv 0.6, then the 4V200 body at Cv 1.0 for a Dia32 bore pushing about 4.0 kgf at 0.5 MPa. If your Dia16 cylinder (1.0 kgf push at 0.5 MPa) only needs slow, precise motion, the 5 cycles per second ceiling here is generous headroom.
Matching a replacement on the M5 code takes four points, since the thread letter is dropped: the 4V100 body, function 10, the M5 port, and then the coil voltage letter plus entry style (blank for the terminal box, I for the 0.5 m pre-wired grommet lead) your panel requires.
Quick checklist
Effective area is 10.2 mm2 (Cv 0.6), maximum switching frequency is 5 cycles per second, and response time is 0.05 s or below. It operates from 0.15-0.8 MPa with a 1.2 MPa proof pressure, over -20 to +70 C on air filtered by a 40 um element, and the aluminium body weighs 120 g with IP65 protection on the coil.
The X0 suffix leaves the coil open, so pick the voltage letter when ordering: A for AC220V (3.5 VA), B for DC24V (2.8 W), C for AC110V (3.5 VA), E for AC24V (4.0 VA) or F for DC12V (2.5 W). Match your PLC or relay output, and state the entry style too - blank for a terminal box or I for the grommet lead with 0.5 m flying wire.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.