verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/2-way Solenoid Valve

Airtac 4V100 Solenoid Valve 4V110M5BI

The AirTAC 4V100 Solenoid Valve 4V110M5BI is a genuine 5/2-way single solenoid (spring return) solenoid valve with M5 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port sizeM5
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$25.55 $33.05Save 22% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V110-M5 stroke, mounting and version on one page All 4V110-M5 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V100 Solenoid Valve 4V110M5BI

The 4V110-M5BI is a 5/2-way single-solenoid pneumatic valve from the compact AirTAC 4V100 series, built to direct compressed air to small double-acting cylinders and actuators. This specific configuration arrives with a DC24V coil and a grommet-style electrical entry—a 0.5 m pre-wired flying lead that simplifies installation in tight benchtop systems. The spool is spring-return, so it requires a constant electrical signal to hold the shifted position; de-energising the coil instantly returns the valve to its home state.

With an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06) and a maximum cycling rate of 5 cycles per second, this valve suits ~Ø16-32 mm cylinders in pick-and-place or clamping duties. The sliding-column spool design responds in 0.05 s or less, and the DC24V coil draws just 2.8 W, keeping thermal load low inside compact enclosures. The M5 threaded ports accept standard push-in fittings, and the IP65-rated body is ready for factory-floor conditions.

Airtac 4V100 Solenoid Valve 4V110M5BI Technical Specifications

ModelAirtac 4V100 Solenoid Valve 4V110M5BI
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port sizeM5
Exhaust portM5
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight120 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V100 Solenoid Valve 4V110M5BI

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-M5Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V100 Solenoid Valve 4V110M5BI Is Used

precision_manufacturing

Benchtop Pick-and-Place

The M5 ports and 0.5 m flying lead fit neatly into benchtop automation cells. The 5/2 spring-return action controls a small double-acting gripper, releasing the part instantly when the signal drops.

settings_input_component

Small Component Clamping

Drives a Ø16 mm or Ø20 mm clamp cylinder on a PCB test fixture. The DC24V grommet entry simplifies wiring through a cable chain, and the 2.8 W coil keeps the control cabinet cool.

science

Laboratory Actuator Control

Directs a miniature double-acting slide table in a diagnostic instrument. The 10.2 mm² effective area provides smooth, repeatable motion, and the IP65 body tolerates occasional fluid splashes.

Is the Airtac 4V100 Solenoid Valve 4V110M5BI the Right Valve?

Choose the 4V110-M5BI when you need a small, spring-return 5/2 valve with a pre-wired DC24V connection. The M5 port size is ideal for micro-cylinders and low-flow actuators where space is at a premium. If your cylinder is larger than ~32 mm bore or you need a higher cycle rate, step up to the 4V200 body (Cv 1.0) for greater flow capacity.

For replacement, match all five points: body size (4V100), function (single solenoid 5/2), port and thread (M5), coil voltage (DC24V), and electrical entry (grommet with flying lead). A terminal-box version of this valve exists under a different SKU; confirm the entry style before ordering. If the application cannot tolerate spring-return on power loss, consider the double-solenoid 4V120 series for a memory-hold function.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V100 Solenoid Valve 4V110M5BI FAQ

With an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06), this valve is best matched to double-acting cylinders in the ~Ø16-32 mm range. It can cycle at up to 5 times per second, making it suitable for light, fast automation tasks. For cylinders above 32 mm bore, a 4V200-series valve (Cv 1.0) will provide a more responsive stroke.

The 'B' specifies a DC24V coil (2.8 W power consumption), and the 'I' indicates a grommet-style electrical entry with a 0.5 m flying lead. This pre-wired lead allows you to connect the valve directly to a control system without needing a separate terminal box or connector, which is especially handy in space-constrained installations.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V100 Solenoid Valve 4V110M5BI

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V110M5BI and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.