The AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V120-06E is a double-solenoid 5/2-way pneumatic directional valve from the compact 4V100 series, designed to direct compressed air to double-acting cylinders and actuators. Its memory-type spool stays in the last pulsed position when power is removed—held by land friction and balanced pressure, not magnetic latching—making it ideal for applications where the actuator must hold its state without a constant electrical signal.
This specific model comes with an AC24V coil drawing 4.0 VA and uses a terminal box entry with 1/8-inch PT (Rc) tapered threads. With an effective area of 10.2 mm² (Cv 0.6) and a response time of 0.05 seconds or less, it suits small-bore double-acting cylinders roughly in the Ø16-32 mm range. The aluminum-alloy body weighs 175 g and operates on filtered air from 0.15 to 0.8 MPa.
| Model | AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E) |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 10.2 mm² (Cv 0.6) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 175 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 10.2 mm² |
|---|---|
| Flow coefficient | Cv 0.6 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
A small material gate on a benchtop sorter that must stay open or closed after a brief PLC pulse. The memory spool holds the gate position without continuous power, reducing coil heat and energy use.
A pneumatic clamp on a rotary index table that needs to remain engaged during a dwell period. The double-solenoid valve keeps the clamp pressurized after the control signal drops, freeing the controller for other tasks.
A small arbor press cycling a double-acting cylinder. The AC24V coil integrates easily with existing control transformers, and the 0.05 s response keeps the press stroke crisp and repeatable.
Choose the 4V120-06E when your circuit needs a 5/2 double-solenoid valve that retains its last position after a pulse, eliminating the need for a continuous holding signal. Its 10.2 mm² effective area (Cv 0.6) fits small automation tasks; if you are driving a larger cylinder or need a faster cycle rate, stepping up to the 4V200 body (Cv 1.0) is recommended.
When replacing an existing valve, match all five points: body size (4V100), function (double solenoid 5/2), port size and thread (1/8-inch PT), coil voltage (AC24V), and electrical entry (terminal box). For a multi-station setup, this valve can be mounted on a common manifold base to simplify plumbing and reduce assembly time.
Quick checklist
The memory spool holds its last position, but the valve alone is not a safety device for suspended or vertical loads. Air leakage across the spool can allow cylinder drift over time. For guaranteed load holding, add a pilot-operated check valve at the cylinder ports or a mechanical brake.
The 4V110 is spring-return and needs a constant signal to stay shifted; it defaults to its rest position when de-energized. The 4V120 is a double-solenoid memory valve—a pulse to one coil shifts it, and it stays there until a pulse is sent to the opposite coil. No holding current is required.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.