AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E)

The AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port sizePT1/8
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$40.70 $48.20Save 15% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V120-06 stroke, mounting and version on one page All 4V120-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E)

The AirTAC 4V120-06E is a double-solenoid 5/2-way pneumatic directional valve from the compact 4V100 series, designed to direct compressed air to double-acting cylinders and actuators. Its memory-type spool stays in the last pulsed position when power is removed—held by land friction and balanced pressure, not magnetic latching—making it ideal for applications where the actuator must hold its state without a constant electrical signal.

This specific model comes with an AC24V coil drawing 4.0 VA and uses a terminal box entry with 1/8-inch PT (Rc) tapered threads. With an effective area of 10.2 mm² (Cv 0.6) and a response time of 0.05 seconds or less, it suits small-bore double-acting cylinders roughly in the Ø16-32 mm range. The aluminum-alloy body weighs 175 g and operates on filtered air from 0.15 to 0.8 MPa.

AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E) Technical Specifications

ModelAirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E)
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port sizePT1/8
Exhaust portPT1/8
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight175 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E)

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-06Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E) Is Used

precision_manufacturing

Pulse-Controlled Gate

A small material gate on a benchtop sorter that must stay open or closed after a brief PLC pulse. The memory spool holds the gate position without continuous power, reducing coil heat and energy use.

tune

Holding a Clamp State

A pneumatic clamp on a rotary index table that needs to remain engaged during a dwell period. The double-solenoid valve keeps the clamp pressurized after the control signal drops, freeing the controller for other tasks.

build

Compact Press Actuation

A small arbor press cycling a double-acting cylinder. The AC24V coil integrates easily with existing control transformers, and the 0.05 s response keeps the press stroke crisp and repeatable.

Is the AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E) the Right Valve?

Choose the 4V120-06E when your circuit needs a 5/2 double-solenoid valve that retains its last position after a pulse, eliminating the need for a continuous holding signal. Its 10.2 mm² effective area (Cv 0.6) fits small automation tasks; if you are driving a larger cylinder or need a faster cycle rate, stepping up to the 4V200 body (Cv 1.0) is recommended.

When replacing an existing valve, match all five points: body size (4V100), function (double solenoid 5/2), port size and thread (1/8-inch PT), coil voltage (AC24V), and electrical entry (terminal box). For a multi-station setup, this valve can be mounted on a common manifold base to simplify plumbing and reduce assembly time.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E) FAQ

The memory spool holds its last position, but the valve alone is not a safety device for suspended or vertical loads. Air leakage across the spool can allow cylinder drift over time. For guaranteed load holding, add a pilot-operated check valve at the cylinder ports or a mechanical brake.

The 4V110 is spring-return and needs a constant signal to stay shifted; it defaults to its rest position when de-energized. The 4V120 is a double-solenoid memory valve—a pulse to one coil shifts it, and it stays there until a pulse is sent to the opposite coil. No holding current is required.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V120-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V12006E)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V12006E and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.