The AirTAC 4V100 Solenoid Valve 4V120M5B is a genuine 5/2-way double solenoid (memory) solenoid valve with M5 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V120-M5B is a 5/2-way double-solenoid valve that directs compressed air to double-acting cylinders and actuators, using the 4V100 compact body with M5 threaded ports. Because it is a double-solenoid design, the spool stays in the last pulsed position when both coils are de-energised—held by land friction and balanced pressure, with no holding current required. This memory characteristic makes it ideal for circuits where the actuator must remain in place after a brief signal.
With an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06) and a maximum cycling rate of 5 cycles per second, this valve suits ~Ø16–32 mm double-acting cylinders in indexing and clamping tasks. The DC24V coil draws just 2.8 W, and the valve responds in 0.05 s or less. Weighing 175 g, the aluminium-alloy body carries an IP65 protection rating and can be mounted individually or on a shared manifold base.
| Model | Airtac 4V100 Solenoid Valve 4V120M5B |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | M5 |
| Exhaust port | M5 |
| Effective area (Cv) | 10.2 mm² (Cv 0.6) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 175 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 10.2 mm² |
|---|---|
| Flow coefficient | Cv 0.6 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -M5 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
Pulse the clamp closed and the 4V120-M5B holds pressure without a continuous signal, saving energy and reducing coil heat in DC24V jigs.
Direct small double-acting cylinders that sort parts on benchtop conveyors. The memory function keeps the gate in position between pulses.
Control grippers and syringe pumps in analytical instruments. The M5 ports and 2.8 W DC coil fit neatly into space-constrained lab modules.
Choose the 4V120-M5B when your circuit needs a 5/2-way valve that holds its last position after a short electrical pulse—no continuous signal needed. The M5 porting keeps the footprint small for benchtop fixtures and compact pneumatic panels. If your cylinder is larger than ~32 mm bore or you need higher flow for faster stroking, step up to the 4V200 series (Cv 1.0) with 1/8" or 1/4" ports.
For direct replacement, match five points: 4V100 body size, function 20 (double solenoid 5/2), M5 port thread, DC24V coil voltage, and terminal-box electrical entry. The valve can be used as a single station or combined with other 4V100 units on a manifold base—order the base separately if you plan to gang multiple valves.
Quick checklist
With an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06), it suits double-acting cylinders roughly Ø16–32 mm in typical short-stroke applications. For larger bores or very high-speed cycling, consider moving to the 4V200 series for greater flow capacity.
No. As a double-solenoid 5/2 valve, the spool remains in the last pulsed position through friction and pressure balance. It does not use magnetic latching or a holding current, so it stays put even if power is removed—but it is not a safety-rated holding device for suspended loads.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.