AirTAC 4V Series · 5/2-way Solenoid Valve

Airtac 4V100 Solenoid Valve 4V120M5C

The AirTAC 4V100 Solenoid Valve 4V120M5C is a genuine 5/2-way double solenoid (memory) solenoid valve with M5 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port sizeM5
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$40.70 $48.20Save 15% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V120-M5 stroke, mounting and version on one page All 4V120-M5 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V100 Solenoid Valve 4V120M5C

The AirTAC 4V120-M5C is a 5/2-way double-solenoid pneumatic valve built on the compact 4V100 body, directing compressed air to double-acting cylinders and actuators. Its defining characteristic is a memory spool: a momentary pulse to either coil shifts the valve, and the spool then stays locked in that last-commanded position by land friction and balanced pressure—no holding current, no spring return. This makes it ideal for applications where the valve must retain its state even if the electrical signal is removed, without consuming continuous power.

With M5 threaded ports and an AC110V coil drawing 3.5 VA, this model suits miniature benchtop automation. The 4V120 delivers an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06) and a rapid response time of 0.05 s or less, comfortably cycling small-bore cylinders in the ~Ø16-32 mm range at up to 5 cycles per second. The aluminum-alloy body weighs 175 g and carries an IP65 protection rating, ensuring reliable service in dry, non-corrosive industrial environments.

Airtac 4V100 Solenoid Valve 4V120M5C Technical Specifications

ModelAirtac 4V100 Solenoid Valve 4V120M5C
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port sizeM5
Exhaust portM5
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight175 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V100 Solenoid Valve 4V120M5C

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-M5Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V100 Solenoid Valve 4V120M5C Is Used

precision_manufacturing

Miniature Part Clamping

Pulse the 4V120-M5C to clamp a delicate electronic component in a test fixture. The memory spool holds clamping force without coil heating, protecting the part during extended dwells.

science

Benchtop Fluidic Sampling

In a lab automation setup, use this valve to divert a reagent stream. The double-solenoid memory ensures the flow path stays fixed after a brief trigger, ideal for sequential analysis routines.

settings_input_component

Pick-and-Place Gripper Control

Command a small parallel gripper on a Cartesian robot. The 4V120-M5C's M5 ports connect directly to the gripper, and the memory function keeps the part secure between moves without continuous power.

Is the Airtac 4V100 Solenoid Valve 4V120M5C the Right Valve?

Choose the 4V120-M5C when your compact machine sequence requires a valve to hold its last position without a sustained electrical signal, such as a clamp that must stay closed during a power-saving mode. The M5 port interface is a direct fit for micro-cylinders and grippers. If your cylinder bore exceeds 32 mm or you need more flow for faster actuation, step up to the 4V200 series (Cv 1.0) with its larger 1/8" or 1/4" ports.

For replacement, match five points precisely: body size (4V100), function (double solenoid 5/2, code 20), port and thread (M5), coil voltage (AC110V), and electrical entry (terminal box). The 4V120 can be mounted individually or ganged on a manifold base, simplifying air supply and wiring for multi-station setups. Always confirm that the system's holding requirements are met by the valve's memory function alone, or add a pilot-operated check valve if absolute load security is required.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V100 Solenoid Valve 4V120M5C FAQ

With an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06), it is well-matched to double-acting cylinders in the ~Ø16-32 mm range for typical cycling. It can physically connect to larger cylinders via M5 fittings, but actuation speed will drop. For bores above 32 mm, consider the 4V200 series.

A momentary electrical pulse shifts the internal spool to one side, where it remains held by friction and balanced air pressure—no springs or magnets are involved. While this holds the valve position on power loss, it is not a safety-rated load brake. For suspended or critical vertical loads, you must add a mechanical brake or a pilot-operated check valve at the cylinder ports.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V100 Solenoid Valve 4V120M5C

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V120M5C and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.