The AirTAC 4V100 Solenoid Valve 4V130CM5B is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with M5 ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Closed center
  • Port sizeM5
  • Effective area8.6 mm²
  • Flow (Cv)0.51
  • Series4V100
$51.14 $58.64Save 12% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V130C-M5 stroke, mounting and version on one page All 4V130C-M5 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V100 Solenoid Valve 4V130CM5B

The 4V130C-M5B is a 5/3-way double-solenoid valve built on the compact 4V100 body, using an M5 threaded port for direct mounting on miniature actuators. When both coils are de-energised, the closed center spool blocks all ports—this traps air on both sides of a double-acting cylinder, holding the piston in position for small clamping or precision-stop tasks. With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06) and a response time of 0.05 s or less, it suits ~Ø16–32 mm cylinders in benchtop automation.

This SKU is configured for DC24V operation with a 2.8 W coil and a standard terminal-box electrical entry. The aluminum-alloy body weighs 200 g and is rated IP65, so it tolerates wash-down-adjacent environments when properly wired. Because the center position blocks flow rather than exhausting, it helps hold a static load briefly during an emergency stop—though for true load-holding safety you must add a pilot-operated check valve at the cylinder ports.

Closed-center stopping is not a load-holding or safety function: air leakage can let the cylinder creep, so add a pilot check valve or a mechanical brake where a load must be held.

Airtac 4V100 Solenoid Valve 4V130CM5B Technical Specifications

ModelAirtac 4V100 Solenoid Valve 4V130CM5B
Series4V100 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Closed center
Port sizeM5
Exhaust portM5
Effective area (Cv)8.6 mm² (Cv 0.51)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight200 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area8.6 mm²
Flow coefficientCv 0.51
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V100 Solenoid Valve 4V130CM5B

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-M5Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V100 Solenoid Valve 4V130CM5B Is Used

precision_manufacturing

Miniature Clamp & Hold

A small pneumatic clamp on a benchtop fixture extends, then the 4V130C-M5B centers to trap air and hold clamping force without continuous air consumption, keeping a delicate part secure during laser marking.

science

Lab Automation Positioning

In a syringe-pump or sample-handling module, the closed center stops a double-acting actuator precisely at an intermediate dispense point.

build

Compact Assembly Stop

On a small pick-and-place unit, the valve halts the vertical axis mid-travel so a vacuum cup can pause for a vision check, then resumes the cycle without the cylinder sagging.

Is the Airtac 4V100 Solenoid Valve 4V130CM5B the Right Valve?

Choose the 4V130C-M5B when you need a small-body 5/3 valve that stops a double-acting cylinder mid-stroke and holds it there, all within an M5 port footprint. If your cylinder is larger than ~32 mm bore or you need faster cycling, step up to the 4V200 series (Cv 1.0) for higher flow. The closed-center spool is ideal when drifting under load is unacceptable during a pause, whereas an exhaust-center (30E) would let the cylinder float.

For a direct replacement, match five points: 4V100 body size, 5/3 closed-center function (30C), M5 port, DC24V coil, and terminal-box entry. If you are building a multi-station manifold, this valve mounts on a 4V100-series base; just confirm your base’s station pitch and the M5 sub-plate porting before ordering.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V100 Solenoid Valve 4V130CM5B FAQ

With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06) and a max frequency of 3 cycles per second, it suits double-acting cylinders roughly in the Ø16–32 mm range for typical 0.15–0.8 MPa supply. For larger bores or faster stroke rates, consider moving to a 4V200-series valve with Cv 1.0.

Both solenoids de-energise and the spool springs to the center position, blocking pressure and both cylinder ports. The piston stops and is held by the trapped air volume. This provides a temporary position hold, but for suspended loads or long-term safety you must add an external pilot-operated check valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V100 Solenoid Valve 4V130CM5B

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V130CM5B and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.