The AirTAC 4V100 Solenoid Valve 4V130CM5B is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with M5 ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V130C-M5B is a 5/3-way double-solenoid valve built on the compact 4V100 body, using an M5 threaded port for direct mounting on miniature actuators. When both coils are de-energised, the closed center spool blocks all ports—this traps air on both sides of a double-acting cylinder, holding the piston in position for small clamping or precision-stop tasks. With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06) and a response time of 0.05 s or less, it suits ~Ø16–32 mm cylinders in benchtop automation.
This SKU is configured for DC24V operation with a 2.8 W coil and a standard terminal-box electrical entry. The aluminum-alloy body weighs 200 g and is rated IP65, so it tolerates wash-down-adjacent environments when properly wired. Because the center position blocks flow rather than exhausting, it helps hold a static load briefly during an emergency stop—though for true load-holding safety you must add a pilot-operated check valve at the cylinder ports.
Closed-center stopping is not a load-holding or safety function: air leakage can let the cylinder creep, so add a pilot check valve or a mechanical brake where a load must be held.
| Model | Airtac 4V100 Solenoid Valve 4V130CM5B |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | M5 |
| Exhaust port | M5 |
| Effective area (Cv) | 8.6 mm² (Cv 0.51) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 200 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 8.6 mm² |
|---|---|
| Flow coefficient | Cv 0.51 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -M5 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
A small pneumatic clamp on a benchtop fixture extends, then the 4V130C-M5B centers to trap air and hold clamping force without continuous air consumption, keeping a delicate part secure during laser marking.
In a syringe-pump or sample-handling module, the closed center stops a double-acting actuator precisely at an intermediate dispense point.
On a small pick-and-place unit, the valve halts the vertical axis mid-travel so a vacuum cup can pause for a vision check, then resumes the cycle without the cylinder sagging.
Choose the 4V130C-M5B when you need a small-body 5/3 valve that stops a double-acting cylinder mid-stroke and holds it there, all within an M5 port footprint. If your cylinder is larger than ~32 mm bore or you need faster cycling, step up to the 4V200 series (Cv 1.0) for higher flow. The closed-center spool is ideal when drifting under load is unacceptable during a pause, whereas an exhaust-center (30E) would let the cylinder float.
For a direct replacement, match five points: 4V100 body size, 5/3 closed-center function (30C), M5 port, DC24V coil, and terminal-box entry. If you are building a multi-station manifold, this valve mounts on a 4V100-series base; just confirm your base’s station pitch and the M5 sub-plate porting before ordering.
Quick checklist
With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06) and a max frequency of 3 cycles per second, it suits double-acting cylinders roughly in the Ø16–32 mm range for typical 0.15–0.8 MPa supply. For larger bores or faster stroke rates, consider moving to a 4V200-series valve with Cv 1.0.
Both solenoids de-energise and the spool springs to the center position, blocking pressure and both cylinder ports. The piston stops and is held by the trapped air volume. This provides a temporary position hold, but for suspended loads or long-term safety you must add an external pilot-operated check valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.