The AirTAC AirTAC 4V130E-06 Solenoid Valve, 4V100 Series (4V130E06A-AM) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with AM ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V130E06A-AM is the 4V100-series 5/3-way valve with an exhaust-center spool: when neither solenoid is energised, the cylinder ports A and B are vented while supply is blocked, so a double-acting actuator can be moved freely by hand or drifts with its load. Two AC220V pulses set the direction; each is held by the balanced spool rather than a spring, and the AMISCO (Italian) coil fitted in place of the standard AirTAC coil carries the same 220V ordering code.
As a 5/3 body this valve flows 8.6 mm2 of effective area (Cv 0.51), so it suits cylinders of roughly O16-32 mm bore where a free-floating center stroke matters more than raw speed. Switching time stays at 0.05 s or below, maximum cycling is 3 cycles per second, and the complete PT 1/8 valve weighs only 200 g. Confirm the exact AMISCO coil VA rating with us at order stage.
| Model | AirTAC 4V130E-06 Solenoid Valve, 4V100 Series (4V130E06A-AM) |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | AM |
| Exhaust port | AM |
| Effective area (Cv) | 8.6 mm² (Cv 0.51) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 200 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 8.6 mm² |
|---|---|
| Flow coefficient | Cv 0.51 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -AM | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
Operators can slide a small fixture or workpiece by hand between powered cycles, because the exhaust center vents both cylinder lines the moment both solenoids drop out.
Light horizontal slides on benchtop automation drift to a natural stop at center, letting downstream sensors or a mechanical stop set the rest position without valve control.
In bench experiments the floating center lets a technician reposition a O16-32 mm double-acting actuator freely during changeovers, with AC220V switching straight from mains-side control.
Choose this exhaust-center 4V130E only when you specifically need the actuator to float at standstill - for load-holding tasks pick the 30C closed-center version instead. If your cylinder exceeds about O32 mm bore or your cycle demands more than Cv 0.51, move up to the 4V200 series (Cv 1.0). A single standalone valve covers small panels; on multi-valve machines, order it on a base so it joins an integrated 4V100 manifold group. When reordering, match five points: 4V100 body, 5/3 exhaust (30E) function, 1/8in PT port, AC220V coil, terminal entry - and specify the -AM suffix again if you need the AMISCO coil repeated.
Quick checklist
It is built for double-acting cylinders and actuators of approximately O16-32 mm bore. As a 5/3-way body its effective area is 8.6 mm2 (Cv 0.51) with a maximum of 3 cycles per second, so keep stroke speeds modest compared with the 5/2 versions of the same 4V100 body.
With both solenoids off, ports A and B are exhausted and the cylinder floats - useful for manual jogging, but not a holding function: fit pilot-operated check valves or a mechanical brake if a load must be secured. The -AM option substitutes an AMISCO (Italian) coil on the same AC220V terminal-entry valve; the electrical VA rating of that coil is not in our standard data, so please confirm it with us.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.