The AirTAC 4V100 Solenoid Valve 4V130EM5-X0 is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with M5 ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V130EM5-X0 is the M5-ported version of AirTAC's 5/3 exhaust-center valve in the 4V100 family. Two solenoids set the spool either way; at center, both cylinder ports A and B are opened to exhaust, leaving a double-acting actuator free to float so operators can position it by hand. The spool's effective area is 8.6 mm2 (Cv 0.51, catalog figure for the 4V130C-06), a good match for double-acting cylinders of roughly O16-32 mm bore fed by short M5 tubing runs.
Because M5 is the smallest port the 4V100 series offers, this variant suits space-critical micro pneumatics: benchtop dispensers, small grippers and laboratory motion stages. No coil voltage is encoded in this SKU, so nominate AC220V, AC110V, AC24V, DC24V or DC12V with your enquiry - the valve ships with terminal-box wiring. It weighs 200 g, shifts in 0.05 s or less, and can sit on a manifold base to build up multi-valve groups.
| Model | Airtac 4V100 Solenoid Valve 4V130EM5-X0 |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | M5 |
| Exhaust port | M5 |
| Effective area (Cv) | 8.6 mm² (Cv 0.51) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 200 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 8.6 mm² |
|---|---|
| Flow coefficient | Cv 0.51 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -M5 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
Driving an O16 mm double-acting parallel gripper on a benchtop assembly cell, the Cv 0.51 (catalog figure for the 4V130C-06) spool gives crisp 0.05 s shifts, while the exhaust center lets an operator glide the gripper open during manual part-loading.
On a laboratory sample-handling stage, a small double-acting slide cylinder (O16-20 mm) is advanced by one coil and retracted by the other; the float center lets technicians position vials by hand between automated runs.
A compact rack-and-pinion rotary actuator indexing a small electronics test fixture benefits from the exhaust center: between index pulses the table can be turned freely for setup, then run automatically at up to 3 cycles per second.
This is the bottom of the 4V100 port ladder - no smaller port exists in the series, so if M5 still flows more than your micro-actuator needs, throttle at the speed controller rather than downsizing the valve. Step up first to 4V130E-06, which keeps the identical 8.6 mm2 / Cv 0.51 (catalog figure for the 4V130C-06) spool but moves to 1/8-inch ports that add less restriction on longer air lines, then to the 4V200 body at Cv 1.0 for larger bores or quicker cycles.
When replacing an existing unit, confirm five things before ordering: 4V100 body, function 30E exhaust center, M5 port (no thread letter applies), coil voltage, and terminal versus grommet entry. Pilot supply can be taken internally or from an external line.
AirtacDistr lists every 4V130E-M5 order code with its price on one page at https://airtacdistr.com/products/airtac-4v130e-m5-solenoid-valve
Quick checklist
Key figures: Cv 0.51 (catalog figure for the 4V130C-06) with an 8.6 mm2 effective area, a maximum of 3 cycles per second, and an activating response of 0.05 s or below. It runs on 0.15-0.8 MPa (proof 1.2 MPa) between -20 and +70 C, weighs 200 g, and meets IP65 with B-class insulation.
This SKU leaves the coil open: pick AC220V (3.5 VA), AC110V (3.5 VA), AC24V (4.0 VA), DC24V (2.8 W) or DC12V (2.5 W), and choose terminal box or grommet entry (I code, 0.5 m flying lead). Beyond that, a direct replacement needs the same 4V100 body, 30E exhaust-center function and M5 port. Note the spool is not magnetically latched - it holds position by land friction and balanced pressure - so a single-solenoid 4V110 is not interchangeable with this double-solenoid model.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.