The AirTAC 4V100 Solenoid Valve 4V130EM5B is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with M5 ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V130E-M5B is a 5/3-way double solenoid valve from the compact AirTAC 4V100 series, configured with an exhaust center and M5 threaded ports. When both solenoids are de-energised, the spool moves to the center position where cylinder ports A and B are exhausted to atmosphere, allowing the actuator to float freely—ideal for applications where the load must be moved manually or settle without air resistance during an emergency stop.
This DC24V terminal-box model draws just 2.8 W and delivers a response time of 0.05 s or less. With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06), it suits double-acting cylinders roughly Ø16–32 mm. The aluminum-alloy body weighs 200 g and carries an IP65 protection rating, making it a reliable choice for benchtop automation and compact pick-and-place systems.
| Model | Airtac 4V100 Solenoid Valve 4V130EM5B |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | M5 |
| Exhaust port | M5 |
| Effective area (Cv) | 8.6 mm² (Cv 0.51) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 200 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 8.6 mm² |
|---|---|
| Flow coefficient | Cv 0.51 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -M5 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
The exhaust center lets operators move a small gripper or slide by hand during setup without fighting trapped air pressure, speeding changeovers on benchtop assembly cells.
Drives a double-acting sampling syringe. At center, both cylinder ports vent, so the piston can be retracted freely for cleaning or manual stroke adjustment between tests.
Controls a Ø20 mm double-acting cylinder on a miniature Z-axis. The 5/3 exhaust center prevents pressure lock, allowing the carriage to drop gently if power is interrupted.
Choose the 4V130E-M5B when your circuit needs a 5/3 exhaust center function on a small manifold or direct-mounted base. The M5 thread keeps the footprint minimal, and the DC24V coil is safe for low-voltage control panels. If your cylinder is larger than Ø32 mm or you need a higher cycle rate, step up to the 4V200 series (Cv 1.0) for greater flow capacity.
For a correct replacement, match all five points: 4V100 body size, 5/3 exhaust center function, M5 port, DC24V coil voltage, and terminal-box electrical entry. This valve can be mounted on a 4V100-series manifold base to build a multi-station valve group, simplifying tubing and wiring in tight enclosures.
Quick checklist
With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06), this 4V100 valve is well matched to double-acting cylinders in the Ø16–32 mm range. For larger bores or faster stroke times, consider moving to the 4V200 series (Cv 1.0) to avoid flow restriction.
In the center position, both cylinder ports (A and B) are connected to the exhaust port (R/S), while the pressure port (P) is blocked. This vents all air from the cylinder, allowing the piston rod to move freely under external force—useful for manual positioning or preventing pressure buildup during a stop.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.