The AirTAC 4V100 Solenoid Valve 4V130EM5BI is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with M5 ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V130E-M5BI is an AirTAC 4V100-series 5/3-way pneumatic solenoid valve configured with a double solenoid and an exhaust center position. When neither coil is energized, both cylinder ports are connected to exhaust, allowing a double-acting actuator to move freely—ideal for applications where the load must be manually positioned or the cylinder needs to 'float' without residual pressure. This specific model features an M5 threaded port, a DC24V coil drawing just 2.8 W, and a grommet-style electrical entry with a pre-wired 0.5 m flying lead for fast DIN-rail wiring.
With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06) and a maximum cycling rate of 3 cycles per second, this valve is sized for compact double-acting cylinders roughly in the Ø16–32 mm range. The spool shifts in 0.05 seconds or less, and the IP65-rated enclosure ensures reliable operation in dusty or lightly washed-down environments. The aluminum-alloy body weighs 200 g and can be mounted individually or ganged on a manifold base for multi-station control.
| Model | Airtac 4V100 Solenoid Valve 4V130EM5BI |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | M5 |
| Exhaust port | M5 |
| Effective area (Cv) | 8.6 mm² (Cv 0.51) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 200 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 8.6 mm² |
|---|---|
| Flow coefficient | Cv 0.51 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -M5 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
The exhaust center lets the Z-axis float during manual teach-mode adjustments on small benchtop Cartesian robots, preventing trapped air pressure and making manual positioning effortless.
In a compact fixture using an M5-ported cylinder, de-energizing the valve exhausts both sides of the piston. The clamp opens freely without a spring, simplifying part changeover in electronics assembly.
The 0.5 m grommet lead and 2.8 W DC coil integrate cleanly into a lab instrument's 24 V control system. The exhaust center ensures a syringe pump's piston can be manually retracted during protocol setup.
Choose the 4V130E-M5BI when your small automation cell needs a 5/3 exhaust-center function on an M5 manifold or direct-mount base. The exhaust center is the right call when the cylinder rod must be free of air pressure at idle—common in manual load/unload stations or clamping setups where the tool retracts by gravity. If you need the cylinder to hold position at center instead, switch to the closed-center 4V130C variant.
For a direct replacement, match five points: stick with the 4V100 body size, confirm the 5/3 exhaust-center spool, verify M5 port threads, select DC24V coil voltage, and ensure the grommet (I) entry with flying lead matches your existing wiring harness. If your cylinder is larger than Ø32 mm or you need faster cycle rates, step up to the 4V200 series, which offers a larger Cv of 1.0.
AirtacDistr lists every 4V130E-M5 order code with its price on one page at https://airtacdistr.com/products/airtac-4v130e-m5-solenoid-valve
Quick checklist
When both solenoids are off, the spool sits in the middle and connects both cylinder ports (A and B) to the exhaust port. This means no compressed air is trapped in the cylinder, so the piston rod can be moved freely by hand or by an external force—a state often called 'float'. It is not a holding position.
Yes. The DC24V coil on the 4V100 body draws only 2.8 W and is rated for continuous duty. The grommet entry (I) provides a sealed 0.5 m flying-lead connection, which is convenient for direct wiring into a terminal strip inside a control cabinet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.