verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/3-way Solenoid Valve

AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C)

The AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT1/8 ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Closed center
  • Port sizePT1/8
  • Effective area8.6 mm²
  • Flow (Cv)0.51
  • Series4V100
$51.14 $58.64Save 12% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V130P-06 stroke, mounting and version on one page All 4V130P-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C)

The AirTAC 4V130P-06C is a 5/3-way double-solenoid valve built on the compact 4V100 body, directing compressed air to double-acting cylinders and actuators. Its pressure-center spool design pressurises both cylinder ports when the valve is in the neutral position, which can be used to create a balanced force or to pressurise a closed system for specific holding or testing sequences.

This 1/8" PT-ported model is fitted with an AC110V coil drawing 3.5 VA, making it compatible with common mains control panels. With an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06) and a response time of 0.05 s or less, it is a precise pilot for small-bore cylinders approximately Ø16-32 mm in light automation tasks.

AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C) Technical Specifications

ModelAirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C)
Series4V100 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Closed center
Port sizePT1/8
Exhaust portPT1/8
Effective area (Cv)8.6 mm² (Cv 0.51)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight200 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area8.6 mm²
Flow coefficientCv 0.51
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C)

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-06Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C) Is Used

tune

Pressure Equalisation Circuits

Used in pneumatic systems where both sides of a double-acting cylinder must be brought to line pressure simultaneously at the neutral position, such as in certain press or test rig setups.

handyman

Small Clamping & Holding

Suits light-duty clamping fixtures on benchtop jigs where a balanced pressure center prevents drift in a specific way, controlling a small double-acting clamp cylinder.

science

Laboratory Fluid Control

Directs air in compact lab automation devices, where the 4V100's 8.6 mm² effective area provides adequate flow for small actuators and the pressure center is needed for a specific test sequence.

Is the AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C) the Right Valve?

Choose the 4V130P-06C when your application requires a 5/3 center condition that applies pressure to both cylinder ports at rest, rather than blocking or exhausting them. This is a niche function used in specific clamping or equalisation circuits, so verify that pressure-center logic matches your pneumatic sequence before ordering.

If your cylinder is larger than Ø32 mm or needs a faster fill, consider stepping up to the 4V200 series for its higher Cv of 1.0. For a direct replacement, match all five points: the 4V100 body size, the 5/3 pressure-center function, the 1/8" port with PT thread, the AC110V coil voltage, and the standard terminal box electrical entry.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C) FAQ

In the center (neutral) position, with neither solenoid energised, the valve spool connects the supply port to both cylinder ports (A and B), while the exhaust ports are blocked. This applies equal pressure to both sides of a double-acting cylinder.

The 4V130P-06C has an effective area of 8.6 mm² and a Cv of approximately 0.51. This flow rate is optimised for small-bore double-acting cylinders, typically in the Ø16-32 mm range, and the valve can cycle at up to 3 times per second.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V130P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V130P06C)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V130P06C and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.