The AirTAC 4V220-06 Solenoid Valve, 4V200 Series (4V22006B-W) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V22006B-W is the external-pilot (-W) version of the 4V200-series 5/2 double-solenoid valve, built with a 1/8" PT port, a DC24V coil (3.0 W) and a screw-terminal electrical entry. Its pilot air is supplied through a separate external port rather than tapped from the main line, so the spool keeps switching dependably even when main-line pressure runs low or the circuit works under vacuum or low-pressure conditions.
Functionally it directs compressed air to double-acting cylinders and actuators, alternating between the two sides with an effective area of 17 mm2 (Cv 1) and a switching response of 0.05 s or faster. The double-solenoid spool has no return spring: after a pulse to either coil, it simply stays where it was last set, held by land friction and balanced pressure, with no holding current drawn. At 320 g it fits the mid 4V200 body class and pairs naturally with cylinders in the ~O32-50 mm bore range.
| Model | AirTAC 4V220-06 Solenoid Valve, 4V200 Series (4V22006B-W) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 320 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The external pilot keeps the spool switching where an internally piloted valve would stall - vacuum pick-and-place lines and low-pressure process circuits where the main supply itself cannot drive the pilot stage.
A 17 mm2 (Cv 1) spool cycling at up to 5 c/s drives O32-50 mm clamp and punch cylinders; the memory function holds the last commanded position through an E-stop power cut without drawing coil current.
DC24V terminal wiring drops straight into standard 24 V panel controls, and the 0.05 s response keeps box pushers and product diverters on O32-50 mm cylinders stepping in rhythm with the conveyor.
Choose this SKU when your circuit needs the mid-range 4V200 flow (17 mm2 / Cv 1, up to 5 cycles per second) and a 24 V DC control signal with terminal-box wiring. If your supply pressure is stable and always well above pilot needs, the internally piloted 4V220-06B saves one air line; pick the -W when the main line can sag, run near vacuum, or when you want pilot supply independent of the working circuit. For a smaller cylinder, step down to the 4V100 (Cv 0.6); for a larger bore or faster cycle, move up to the 4V300 (Cv 1.65). A single 5/2 double-solenoid covers most reciprocating double-acting duties - only step to a 5/3 4V230 variant if you need a center position, and consider a manifold base when several valves share one supply.
Ordering a replacement is a five-point match on this exact code: 4V200 body, function 20 (double solenoid, memory), 1/8" port with PT thread, DC24V coil, and terminal entry - plus the -W external-pilot suffix, which must be repeated or the pilot plumbing will not line up.
Quick checklist
-W makes the valve externally piloted: pilot air enters through its own external port instead of being bled from the main supply inside the valve. This keeps switching reliable when line pressure runs low or the circuit operates under vacuum or low pressure. The trade-off is one extra pilot air connection during installation. No minimum pilot-pressure figure is published for this variant - size the pilot supply against your AirTAC application data.
It switches compressed air to double-acting cylinders and actuators with an effective area of 17 mm2 (Cv 1), well matched to O32-50 mm bores, at up to 5 cycles per second. Because the double-solenoid spool is a memory type - held by land friction and balanced pressure, not by a spring or a magnet - the cylinder stays in its last commanded position when 24 V power is lost. That is a hold of convenience, not a certified safety brake: for suspended or hazardous loads, add a pilot-operated check valve at the cylinder ports or a mechanical brake.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.