The AirTAC AirTAC 4V220-08E Solenoid Valve, 5/2-way, PT1/4, AC24V, terminal entry (4V22008E) is a genuine 5/2-way double solenoid (memory) solenoid valve with 22008E ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V220-08E is a 5/2-way double-solenoid pneumatic directional valve built on the proven 4V200 aluminium body. It directs compressed air to both sides of a double-acting cylinder or rotary actuator, and its memory-type spool stays in the last pulsed position even when the AC24V coil is de-energised—no holding current is needed. The spool is retained by land friction and balanced pressure, not by a magnet, so it is ideal for applications where you want a cylinder to hold its end-of-stroke state through a power cycle.
This model carries an AC24V (50/60 Hz) coil drawing 5.0 VA, wired through the standard terminal box entry. With a 1/4-inch PT inlet and outlet and a 1/8-inch PT exhaust, it delivers an effective area of 17.0 mm² (Cv 1.0) and cycles at up to 5 times per second. Response time is 0.05 seconds or less, and the IP65-rated enclosure keeps the sliding-column spool clean in dusty or washdown environments.
| Model | AirTAC 4V220-08E Solenoid Valve, 5/2-way, PT1/4, AC24V, terminal entry (4V22008E) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | 22008E |
| Exhaust port | 22008E |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 320 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -22008E | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The memory spool holds a stop gate open or closed without constant power, reducing coil heat in indexing conveyor systems. The AC24V supply is common in material-handling panels.
A pulsed signal sets the clamp; it stays locked even if the machine control power cycles. The 17.0 mm² effective area provides ample force for mid-bore clamping cylinders.
Use the 4V220-08E to hold a diverter gate in its last commanded position through a production stop. The 5 c/s max frequency handles rapid sortation on small carton lines.
Choose the 4V220-08E when your double-acting cylinder (roughly 32 to 50 mm bore) needs to lock its last position on power loss without a constant electrical signal. If your cylinder is smaller (below 32 mm) and you want to save space, step down to the 4V100 series (Cv 0.6); if you need faster fill on a 63 mm or larger bore, move up to the 4V300 (Cv 1.65). The double-solenoid memory function is the key differentiator from the spring-return 4V210—use it when a machine must not automatically retract on an E-stop.
For a drop-in replacement, match all five elements: the 4V200 body size, the 5/2 double-solenoid function (20), the 1/4-inch PT port, the AC24V coil voltage, and the terminal-box electrical entry. If you are building a multi-valve station, this model mounts directly onto a 4V200 manifold base, letting you gang up to 20 valves with a common supply and exhaust.
Quick checklist
The 4V220-08E is a double-solenoid valve with a memory spool. The spool stays in the position it was last pulsed to, held by friction and balanced air pressure, so the cylinder remains at its end-of-stroke position. It does not use a spring or a magnetic latch. For suspended-load safety, you must add an external pilot-operated check valve or mechanical brake.
No, the 'E' suffix denotes an AC24V (50/60 Hz) coil rated at 5.0 VA. For DC24V, order the 4V220-08B; for AC220V, order the 4V220-08A. The coil is field-replaceable, but you must match the voltage to your control system to avoid burnout.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.