verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/3-way Solenoid Valve

AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W)

The AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT1/4 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Exhaust center
  • Port sizePT1/4
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$53.63 $58.64Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 4V230E-08 stroke, mounting and version on one page All 4V230E-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W)

The AirTAC 4V230E08A-W is a 5/3-way double-solenoid valve with an exhaust center, built on the 4V200 body and fitted with the -W external-pilot option. At center, both cylinder ports A and B vent to exhaust, so a double-acting cylinder floats free and can be moved by hand or by load - useful for staging, manual positioning and safe de-tensioning between cycles. The -W suffix means pilot air is supplied through a separate external port rather than tapped internally from the main line, so spool switching stays reliable in vacuum circuits and on lines where supply pressure may drop. The AC220V coil draws 4.5 VA and terminates in a terminal box for fixed conduit wiring.

Flow capacity sits at an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) with a maximum cycling rate of 3 cycles per second, and the valve responds in 0.05 s or less. Weighing 360 g in an aluminum-alloy body rated IP65, it suits roughly O32-50 mm bore double-acting cylinders and mounts singly or on an integrated manifold base.

AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W) Technical Specifications

ModelAirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W)
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Exhaust center
Port sizePT1/4
Exhaust portPT1/8
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-08Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W) Is Used

precision_manufacturing

Float-and-adjust assembly fixtures

Exhaust center lets operators reposition or free-float a double-acting clamp slide between automatic cycles, then the pulsed solenoid signal re-engages it instantly.

conveyor_belt

Packaging pushers on low-pressure lines

The -W external pilot keeps switching dependable on conveyor pusher circuits where main-line pressure sags, venting the cylinder freely at rest so product is not gripped.

settings_input_component

Manifold stations with staged release

On a 4V200 manifold base, the 30E function de-tensions selected actuators at center while neighbouring valves keep working - handy for changeover and purge steps.

Is the AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W) the Right Valve?

Size within the 4V family by cylinder demand: step down to the 4V100 (Cv 0.6) for small bores with modest speed needs, and step up to the 4V300 (Cv 1.65) when a larger bore or faster cycle calls for more flow. Choose this 30E exhaust-center version when the actuator must float at center; pick the 30C closed center to hold position or the 30P pressure center to pre-charge both sides. Pick a single 4V210 when a spring return suffices, or this double-solenoid 4V230 when a pulsed signal must leave the spool in its last position. Single body or manifold base both work - the valve seats on a common supply base for multi-valve stations.

For replacement, match five points: body size (4V200), function (30E), port and thread (1/4" PT), coil voltage (AC220V), entry (terminal) - and confirm the -W external-pilot option so the pilot plumbing on your machine lines up.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W) FAQ

An internally piloted valve taps its switching air from the main supply, so switching can falter when line pressure falls or in vacuum service. The -W version feeds the pilot from a dedicated external port, keeping spool actuation crisp and the 0.05 s response intact even when the main line is weak. You plumb one extra pilot line, and the valve still carries the 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) flow rating of the standard 4V230 body.

At center, ports A and B both connect to exhaust, so a double-acting cylinder is unpressurised on both sides and floats free - it can drift under load or be moved by hand. That is ideal for staging and manual adjustment, but it is not a brake: if your application must hold a suspended or opposing load in the center position, add a pilot-operated check valve at the cylinder ports or a mechanical brake, because this valve alone will not guarantee load holding.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08A-W)

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 4V230E08A-W and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.