The AirTAC 4V230P-08F Solenoid Valve, 5/3-way, pressure center, PT1/4, DC12V, terminal entry (4V230P08F) is a genuine 5/3-way 5/3 double solenoid — pressure center solenoid valve with PT1/4 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V230P-08F is a 5/3-way double-solenoid valve that directs compressed air to double-acting cylinders with a pressure-center spool arrangement. When both solenoids are de-energized, the spool shifts to its center position, delivering supply pressure to both cylinder ports A and B simultaneously. This creates a balanced force that helps a vertical or heavily loaded cylinder resist drift, though a dedicated mechanical brake or pilot-operated check is still required for true suspended-load safety.
Operating on a 12 V DC coil drawing just 2.5 W, this terminal-box model suits mobile or battery-backed equipment where low-voltage DC is standard. The 4V200 body provides an effective area of 13.6 mm² (Cv 0.8, catalog figure for the 4V230C-08) through its 1/4-inch PT inlet and outlet ports, with a maximum cycling rate of 3 cycles per second. The aluminum-alloy body weighs 360 g, carries an IP65 protection rating, and includes a locking manual override for setup and troubleshooting.
| Model | AirTAC 4V230P-08F Solenoid Valve, 5/3-way, pressure center, PT1/4, DC12V, terminal entry (4V230P08F) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Pressure center |
| Port size | PT1/4 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
In a pick-and-place Z-axis, the pressure-center spool applies balanced pressure to both sides of the cylinder at rest, adding stiffness to the vertical column and reducing sag before the next move command.
For a pneumatic clamp that must maintain a light holding bias without full actuation, the 4V230P-08F pressurizes both ports at center, keeping the clamp jaws in light contact with the workpiece.
In test fixtures where a cylinder must hold a load cell or probe at a mid-stroke position with some resistance to external disturbance, the pressure-center function provides a pneumatic spring effect without continuous solenoid power.
Choose the 4V230P-08F when your double-acting cylinder requires both sides to be pressurized at mid-stroke—common in applications where you want to stiffen the actuator or preload a mechanism without driving it to an end position. The pressure-center function differs from the closed-center 4V230C (which locks air in the ports) and the exhaust-center 4V230E (which vents both ports to atmosphere). If your cylinder bore is under 25 mm, the smaller 4V100 series (Cv 0.6) may be a better fit; for bores above 50 mm or faster cycle rates, step up to the 4V300 (Cv 1.65).
When replacing an existing valve, match five points: the 4V200 body size, the 5/3 pressure-center function (30P), the 1/4-inch port size with PT (Rc) tapered thread, the DC12V coil voltage, and the terminal-box electrical entry. This valve can be mounted individually or on a common manifold base with other 4V200-series units.
Quick checklist
In the center position (both solenoids off), the spool connects the supply port to both cylinder ports A and B. This pressurizes both sides of the double-acting cylinder, creating a balanced force. It is useful for adding stiffness to an axis at mid-stroke, but it is not a safety holding brake—a separate mechanical lock is required for suspended loads.
Yes. The 4V230P-08F is built with a DC12V coil rated at 2.5 W, making it directly compatible with 12 V DC power supplies commonly found on mobile equipment, vehicles, and battery-operated machinery. The terminal-box entry accepts standard wiring; ensure your supply can handle the inrush current when the solenoid energizes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.