The AirTAC AirTAC 4V310-10BI Solenoid Valve, 5/2-way, PT3/8, DC24V, grommet entry (4V31010BI) is a genuine 5/2-way single solenoid (spring return) solenoid valve with 31010BI ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V310-10BI is a 5/2-way single-solenoid pneumatic directional valve that directs compressed air to double-acting cylinders and rotary actuators. Its spool shifts when the DC24V coil is energised and returns by mechanical spring the instant power is removed, making it a safe default-state choice for clamping or ejecting where the cylinder must retract on power loss. With a 28.0 mm² effective area (Cv 1.65) and a response time ≤ 0.05 s, it is sized for ~O50–80 mm bore cylinders.
This specific configuration ships with a grommet-style electrical entry—a 0.5 m pre-wired flying lead that simplifies DIN-rail wiring and keeps the IP65 protection intact. The 3.0 W DC coil runs cool on 24 V control circuits, and the 3/8 in PT (Rc) ports deliver high flow while the 1/4 in exhausts keep the body compact. The aluminium-alloy body weighs 310 g and needs no lubricated air when filtered to 40 µm.
| Model | AirTAC 4V310-10BI Solenoid Valve, 5/2-way, PT3/8, DC24V, grommet entry (4V31010BI) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | 31010BI |
| Exhaust port | 31010BI |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 310 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -31010BI | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Directs a double-acting clamp cylinder on a machining centre. Spring return ensures the clamp releases immediately when the 24 V signal drops, preventing part damage during an E-stop.
Shifts a pneumatic gate on a conveyor line. The 3/8 in port provides the flow to move a ~O63 mm cylinder quickly, while the grommet lead keeps wiring tidy inside a crowded control panel.
Controls the advance stroke of a small pneumatic press. The 3.0 W DC coil interfaces directly with a PLC output, and the 0.05 s response gives crisp punch timing for consistent forming.
Choose the 4V310-10BI when your application needs a single 5/2 valve with a DC24V grommet coil on a 3/8 in PT port. Step down to a 4V200 (Cv 1.0) only if you are driving a cylinder smaller than ~O40 mm; move up to a 4V400 (Cv 2.82) for bores above ~O100 mm. A single-solenoid spring-return valve suits circuits where the cylinder must go to a known safe position when the signal is off—unlike a double-solenoid memory valve that stays put.
For a drop-in replacement match five points: body size (4V300), function (5/2 single solenoid), port and thread (3/8 in PT), coil voltage (DC24V), and electrical entry (grommet with flying lead). If you are building a multi-station manifold, order the same function on a base-compatible sub-plate; the 4V310-10BI can be mounted individually or ganged on a common manifold.
Quick checklist
With a Cv of 1.65 and a 28.0 mm² effective area, it is a good match for double-acting cylinders in the ~O50–80 mm bore range. It can cycle a ~O63 mm cylinder at up to 4 cycles per second under typical 0.5–0.6 MPa shop air.
Yes—the 'I' suffix means the valve comes with a 0.5 m flying lead instead of a terminal box. You connect the two DC24V wires directly to your control circuit. Polarity is marked on the lead, and the grommet maintains the IP65 seal when properly fitted.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.