The AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-AM) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/4 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V32008B-AM is an AirTAC 4V300-series 5/2-way double solenoid valve with PT 1/4in ports, a DC24V coil on terminal entry, and the -AM factory option: an AMISCO (Italian) solenoid coil fitted in place of the standard one. Its memory behavior means a short pulse sets the spool, and the valve simply stays in that last position when power is removed - there is no spring to return it and no holding current is drawn, so the cylinder carries on moving air to whichever port was last pressurised. This is a double-solenoid valve for double-acting cylinders and actuators; it is not a single-solenoid spring-return valve and never needs a constant electrical signal to hold its state.
With an effective area of 28 mm2 (Cv 1.65) and a maximum cycling rate of 4 cycles per second, this 4V300 body sits comfortably in the mid-flow class and suits roughly O50-80 mm bores. Response time is 0.05 s or below, the valve weighs 400 g, and it runs on filtered air at 0.15-0.8 MPa with an IP65-rated terminal box. The valve body and flow characteristics are identical to the standard 4V320-08B - only the coil brand differs - so buyers needing to match the exact AMISCO coil electrical rating should confirm it with us before ordering.
| Model | AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-AM) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Double-acting clamping cylinders on fixtures and jigs stay in their commanded state between cycles because the memory spool holds position without coil power, simplifying PLC output wiring.
Mounted on a manifold base, this DC24V valve groups with other 4V300 bodies into a single supply point for machine tool slides and small presses in the O50-80 mm bore class.
Pushers and diverter actuators on conveyor lines reverse on a brief 24V pulse and remain at the last position through line stops, with Cv 1.65 (catalog figure for the 4V310-10) flow supporting brisk cylinder travel.
Pick this 4V32008B-AM when a double-acting cylinder in the O50-80 mm range needs pulsed two-position control that keeps its last state through a power cut or E-stop of the coil circuit. Drop down to the 4V200 (Cv 1.0) if the bore or speed demand is smaller, and step up to the 4V400 (Cv 2.82) for larger bores or faster cycling. If you need a mid-position instead of a two-state memory, the 4V300 5/3 versions (30C closed, 30E exhaust, 30P pressure) offer it - note they trade flow (21.3 mm2 / Cv 1.25) and frequency (3 c/s) for the center function.
For a like-for-like replacement, match all five points: body size 4V300, function 20 (double solenoid 5/2), port and thread 1/4in PT, coil voltage DC24V, and terminal entry. Also confirm whether your existing valve carries the -AM option - the AMISCO coil variant should be replaced with the same variant to keep spares consistent. A single valve screws directly into the ports, while a base-mounted version lets you build an integrated manifold group on one air supply.
Quick checklist
It directs compressed air to double-acting cylinders and actuators (never single-acting ones) through 1/4in PT ports. The effective area is 28 mm2 with a Cv of 1.65, it cycles up to 4 times per second, and it suits bores of roughly O50-80 mm. AirTAC publishes flow as a chart rather than a single figure, so use the Cv and effective area for sizing.
-AM means this 4V320-08B leaves the factory with an AMISCO (Italian) solenoid coil fitted instead of the standard AirTAC coil. The valve body, 5/2 memory function, PT 1/4in ports and DC24V operation are unchanged. Our data does not list the AMISCO coil's W/VA rating, so please confirm the exact electrical rating with us - do not assume it matches the standard coil's figure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.