The AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/4 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V32008B-W is a 4V300-body 5/2-way double-solenoid valve with the factory -W external-pilot option: pilot air arrives through a dedicated external port instead of being tapped off the main supply, so the spool keeps switching cleanly even on low-pressure mains or in vacuum / low-pressure circuits. It alternates pressure between the two sides of double-acting cylinders and actuators with a 1/4in PT-threaded port, and its memory function means the spool stays in whatever position it was last pulsed to - held by land friction and balanced pressure, with no spring and no holding current - so a brief power cut does not disturb the cycle. Sized at 28 mm2 effective area (Cv 1.65) with a 4 cycle/sec maximum frequency, it suits roughly O50-80 mm bores.
This exact SKU runs on a DC24V coil drawing 3.0 W, wired through a screw terminal box for conduit or ducted installations where a pre-wired lead is not wanted. A sliding-column spool with a 0.05 s or faster response, IP65 protection and a 400 g aluminium body round out the hardware; no lubrication is needed, only air filtered by a 40 um element. Manual override is fitted for testing and setup, and the valve mounts on a base for integrated manifold groups.
| Model | AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
The external pilot keeps switching deterministic where an internally piloted valve would stall - pick-and-place heads, clamping rings and vacuum-assisted tooling running off low or unstable main-line pressure.
Cv 1.65 (catalog figure for the 4V310-10) flow with a memory function drives O50-80 mm double-acting clamp and press cylinders that hold their last commanded stroke through short control-power interruptions.
Conveyor stops, lifting gates and sorting pushers on 24 V DC machine buses benefit from the terminal-box wiring, <=0.05 s response and 4 cycle/sec rate of this 400 g valve.
Pick the 4V300 class when your bore is too big for the 4V200 (Cv 1.0) but the 4V400 (Cv 2.82) would be oversized; this valve sits comfortably in the middle at Cv 1.65 (catalog figure for the 4V310-10). Double solenoid with memory is the right choice where a cylinder must keep travelling or stay put on power loss - for guaranteed load holding on suspended loads, add pilot-operated check valves or a mechanical brake rather than relying on the valve alone. Single valves suit standalone actuators; a manifold base groups several 4V300 valves into one compact supply block.
Replacing an existing unit? Match all five points: body size (4V300), function (double solenoid 5/2 memory), port and thread (1/4in PT), coil voltage (DC24V, 3.0 W) and electrical entry (screw terminal). Confirm the -W external-pilot suffix too - it is not interchangeable with a standard internally piloted 4V320-08B without re-piping the pilot line.
Quick checklist
With 28 mm2 effective area (Cv 1.65) on its 5/2 spool it alternates supply and exhaust for double-acting cylinders in the ~O50-80 mm range at up to 4 cycles per second. The -W suffix feeds pilot air from a separate external port, so switching stays reliable on low-pressure mains or vacuum / low-pressure circuits where an internally piloted valve could fail to shift.
No. The spool simply remains in its last pulsed position - held by land friction and balanced pressure, with no spring and no holding current - but this is not a certified safety device. For suspended loads or any fall-protection duty, fit pilot-operated check valves at the cylinder ports or a dedicated mechanical brake; never rely on the valve alone.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.