AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W)

The AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/4 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port sizePT1/4
  • Effective area28.0 mm²
  • Flow (Cv)1.65
  • Series4V300
$60.43 $65.62Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 4V320-08 stroke, mounting and version on one page All 4V320-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W)

The AirTAC 4V32008B-W is a 4V300-body 5/2-way double-solenoid valve with the factory -W external-pilot option: pilot air arrives through a dedicated external port instead of being tapped off the main supply, so the spool keeps switching cleanly even on low-pressure mains or in vacuum / low-pressure circuits. It alternates pressure between the two sides of double-acting cylinders and actuators with a 1/4in PT-threaded port, and its memory function means the spool stays in whatever position it was last pulsed to - held by land friction and balanced pressure, with no spring and no holding current - so a brief power cut does not disturb the cycle. Sized at 28 mm2 effective area (Cv 1.65) with a 4 cycle/sec maximum frequency, it suits roughly O50-80 mm bores.

This exact SKU runs on a DC24V coil drawing 3.0 W, wired through a screw terminal box for conduit or ducted installations where a pre-wired lead is not wanted. A sliding-column spool with a 0.05 s or faster response, IP65 protection and a 400 g aluminium body round out the hardware; no lubrication is needed, only air filtered by a 40 um element. Manual override is fitted for testing and setup, and the valve mounts on a base for integrated manifold groups.

AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W) Technical Specifications

ModelAirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W)
Series4V300 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port sizePT1/4
Exhaust portPT1/4
Effective area (Cv)28.0 mm² (Cv 1.65)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency4 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight400 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area28.0 mm²
Flow coefficientCv 1.65
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W)

4VSolenoid valve, spool type, 4-series.
3Body size (4V300) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-08Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W) Is Used

precision_manufacturing

Low-pressure and vacuum circuits

The external pilot keeps switching deterministic where an internally piloted valve would stall - pick-and-place heads, clamping rings and vacuum-assisted tooling running off low or unstable main-line pressure.

factory

Bigger-bore clamping and press fixtures

Cv 1.65 (catalog figure for the 4V310-10) flow with a memory function drives O50-80 mm double-acting clamp and press cylinders that hold their last commanded stroke through short control-power interruptions.

local_shipping

Material handling actuators

Conveyor stops, lifting gates and sorting pushers on 24 V DC machine buses benefit from the terminal-box wiring, <=0.05 s response and 4 cycle/sec rate of this 400 g valve.

Is the AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W) the Right Valve?

Pick the 4V300 class when your bore is too big for the 4V200 (Cv 1.0) but the 4V400 (Cv 2.82) would be oversized; this valve sits comfortably in the middle at Cv 1.65 (catalog figure for the 4V310-10). Double solenoid with memory is the right choice where a cylinder must keep travelling or stay put on power loss - for guaranteed load holding on suspended loads, add pilot-operated check valves or a mechanical brake rather than relying on the valve alone. Single valves suit standalone actuators; a manifold base groups several 4V300 valves into one compact supply block.

Replacing an existing unit? Match all five points: body size (4V300), function (double solenoid 5/2 memory), port and thread (1/4in PT), coil voltage (DC24V, 3.0 W) and electrical entry (screw terminal). Confirm the -W external-pilot suffix too - it is not interchangeable with a standard internally piloted 4V320-08B without re-piping the pilot line.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W) FAQ

With 28 mm2 effective area (Cv 1.65) on its 5/2 spool it alternates supply and exhaust for double-acting cylinders in the ~O50-80 mm range at up to 4 cycles per second. The -W suffix feeds pilot air from a separate external port, so switching stays reliable on low-pressure mains or vacuum / low-pressure circuits where an internally piloted valve could fail to shift.

No. The spool simply remains in its last pulsed position - held by land friction and balanced pressure, with no spring and no holding current - but this is not a certified safety device. For suspended loads or any fall-protection duty, fit pilot-operated check valves at the cylinder ports or a dedicated mechanical brake; never rely on the valve alone.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008B-W)

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 4V32008B-W and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.