The AirTAC AirTAC 4V320-10 Solenoid Valve, 4V300 Series (4V32010A-AM-W) is a genuine 5/2-way double solenoid (memory) solenoid valve with W ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V32010A-AM-W is a 5/2-way double-solenoid directional valve built on the 4V300 body, sized for 3/8in PT ports and rated at an effective area of 28 mm2 (Cv 1.65). Because both solenoids position the spool, the valve is a true memory type: it stays in whichever position it was last pulsed to, held by land friction and balanced pressures with no spring and no holding current - it is not magnetically latched, so a momentary pulse is all the control circuit needs.
This specific build carries two factory options. The -W suffix makes it an external-pilot valve: pilot air enters through a separate pilot port instead of being tapped internally from the main line, so switching stays dependable on low main-line pressure or in low-pressure circuits. The -AM suffix fits an AMISCO (Italian) solenoid coil in place of the standard coil on the AC220V, terminal-box version; the valve function and 400 g assembly weight are unchanged, but ask us to confirm the exact AMISCO coil electrical rating before ordering. Like every 4V300 valve it responds in 0.05 s or less, carries IP65 protection, and comfortably serves double-acting cylinders in the ~O50-80 mm bore range.
| Model | AirTAC 4V320-10 Solenoid Valve, 4V300 Series (4V32010A-AM-W) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | W |
| Exhaust port | W |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -W | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Feeds 3/8in-lineserving larger double-acting press and clamp cylinders around O50-80 mm, with Cv 1.65 flow to keep stroke times short at up to 4 cycles per second.
The external-pilot (-W) construction takes pilot air from its own port, so the valve keeps shifting cleanly on machines where main-line pressure runs low or vacuum handling is involved.
Positions grippers, lifts and conveyor stopper cylinders on packaging and palletising lines, retaining the last pulsed state through control-power dips without drawing holding current.
Match this Cv 1.65 class to your bore: drop to the 4V200 (Cv 1.0) for smaller cylinders, or move up to the 4V400 (Cv 2.82) when a larger bore demands more flow. Choose a 20-type double solenoid when you want the actuator to hold its last pulsed state through a power cut; pick the 10-type if you need a spring to return the spool whenever the signal drops, or a 30C/E/P 5/3 version when a definite center condition matters. Run one valve stand-alone or gang several on an integrated manifold base to cut piping. When replacing, verify all five points: 4V300 body, function 20, 3/8in PT ports, AC220V coil, terminal entry - plus the two option codes, since only another -W external-pilot unit will behave the same on a low-pressure supply and only another -AM unit will share the AMISCO coil.
Quick checklist
It is a 5/2 double-solenoid valve for double-acting cylinders and actuators, pressurising one port while exhausting the other. With an effective area of 28 mm2 (Cv 1.65) and a 3/8in PT main port, it suits roughly O50-80 mm bores and switches up to 4 cycles per second at 0.15-0.8 MPa. Single-acting cylinders need a 3/2 valve, not this model.
-AM means the AC220V coil is an AMISCO (Italian) unit rather than the standard coil; -W means external pilot, so pilot air is supplied through a separate port. Mechanically it replaces a 4V320-10A one-for-one (same 4V300 body, 5/2 memory function, 3/8in PT, 400 g), but on a -W valve you must pipe the pilot port, and the AMISCO coil rating should be confirmed with us before reuse.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.