The AirTAC 4V320-10 Solenoid Valve, 4V300 Series (4V32010B-AM) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT3/8 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V32010B-AM is a 4V300-series 5/2-way double solenoid valve with a 3/8 PT inlet and outlet, a 1/4 exhaust and a DC24V coil wired through a terminal box. This -AM version leaves the factory fitted with an Italian AMISCO solenoid coil in place of the standard AirTAC coil; the body, ports and flow path are unchanged. As a double-solenoid spool valve it has no return spring: the spool simply stays in whichever position it was last pulsed to, held by land friction and balanced pressure, with no holding current drawn. It is not magnetically latched, and for suspended loads a pilot-operated check valve or mechanical brake should be added at the cylinder.
Flow capacity sits in the 4V300 class at 28.0 mm2 effective area (Cv 1.65), with a maximum cycling rate of 4 cycles per second and an activating time of 0.05 s or less. That sizing comfortably serves double-acting cylinders in the ~O50-80 mm range. The valve weighs 400 g, runs on 0.15-0.8 MPa filtered air, carries IP65 protection and mounts singly or on an integrated manifold base. Confirm the exact AMISCO coil rating with us when ordering.
| Model | AirTAC 4V320-10 Solenoid Valve, 4V300 Series (4V32010B-AM) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Shifts the air supply on double-acting cylinders driving slides and tool clamps around ~O50-80 mm, where the 28.0 mm2 orifice keeps strokes brisk at up to 4 cycles per second.
Base-mounted banks of 4V320 valves switch gripper and pusher cylinders along packaging and assembly lines, with each spool holding its pulsed state between commands.
Energising one coil clamps a part or pallet and the position stays put after the pulse ends, suiting lift-and-locate fixtures on conveyors and palletisers.
Size within the AirTAC range by bore: drop to the 4V200 (Cv 1.0) for cylinders below ~O50 mm, stay on this 4V300 body for ~O50-80 mm, or step up to the 4V400 (Cv 2.82) for larger bores or faster cycling. Choose the single-solenoid 4V310 if you need a spring return that vents on signal loss; pick this double-solenoid 4V320 when the actuator must remember its last pulsed position; specify a 5/3 (30C/E/P) version only if the center condition matters. A single valve suits isolated stations, while a base-mounted arrangement lets several 4V300 valves share one manifold.
When reordering or cross-checking, match five points: body size (4V300), function (double solenoid 5/2), port and thread (3/8 PT, 1/4 exhaust), coil voltage (DC24V) and electrical entry (terminal box). Keep the -AM suffix if the AMISCO coil must be preserved; the plain 4V320-10B is the standard-coil equivalent.
Quick checklist
It directs compressed air to double-acting cylinders and actuators, best matched to ~O50-80 mm bores. The 5/2 flow path offers 28.0 mm2 effective area (Cv 1.65), cycles up to 4 times per second and responds in 0.05 s or less, so it is a step above the 4V200 (Cv 1.0) and below the 4V400 (Cv 2.82).
The -AM suffix means this valve is built with an AMISCO (Italian) solenoid coil instead of the standard AirTAC coil, and our published coil-power figures cover the standard coil only. The ordered DC24V voltage still applies, but please confirm the exact AMISCO coil rating with us before designing your power supply or wiring.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.