The AirTAC 4V320-10C Solenoid Valve, 5/2-way, PT3/8, AC110V, terminal entry (4V32010C) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT3/8 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V320-10C is a 5/2-way double-solenoid pneumatic directional valve built on the 4V300 body platform. It directs compressed air to double-acting cylinders and actuators using a memory-spool design: a momentary pulse to either coil shifts the spool, and it stays in that last-commanded position without holding current—ideal for applications where you need the actuator to remain stationary if a control signal is interrupted.
This specific configuration carries an AC110V coil drawing 4.5 VA and uses a standard terminal-box electrical entry with PT (Rc) tapered pipe threads on its 3/8-inch supply and output ports. The valve body delivers an effective area of 28.0 mm² (Cv 1.65), suiting it to cylinders in the ~50-80 mm bore range. At 400 grams, it provides a robust yet compact solution with a response time of 0.05 seconds or below and IP65-rated protection.
| Model | AirTAC 4V320-10C Solenoid Valve, 5/2-way, PT3/8, AC110V, terminal entry (4V32010C) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
The memory spool holds a diverter gate in its last position during a control panel power cycle, preventing product misroutes without needing a constant signal to the coil.
A pulsed signal sets the clamp; the 4V320-10C holds pressure on the part even if the PLC output drops, reducing the risk of workpiece movement during a tool change.
With a 28.0 mm² effective area, this valve fills and exhausts ~63-80 mm bore cylinders quickly, giving a clean, sharp stroke on light-press and forming operations.
Step up to this 4V320-10C when your double-acting cylinder needs the 1.65 Cv flow of the 4V300 series—if you are running a smaller bore (under ~40 mm), the 4V200 body (Cv 1.0) may be a better fit, while a 4V400 (Cv 2.82) handles larger actuators. The double-solenoid memory function is the right call when the valve must hold its last state on power loss; if your circuit requires the spool to return to a home position when de-energised, choose the single-solenoid 4V310 instead.
For a direct replacement, match five points: the 4V300 body size, the 5/2 double-solenoid function (code 20), the 3/8-inch PT port, an AC110V coil, and the terminal-box entry. This valve can be mounted individually or ganged on a common manifold base when you are building a multi-station valve group.
Quick checklist
It is typically matched with double-acting cylinders in the ~50-80 mm bore range. The valve’s 28.0 mm² effective area (Cv 1.65) provides sufficient flow for these sizes at standard industrial speeds; for bores above 100 mm, consider stepping up to the 4V400 series.
No. The 4V320-10C holds its spool position purely through land friction and balanced air pressure after the pulse ends—there is no spring return, residual magnetism, or magnetic detent. It simply stays where it was last commanded. For a guaranteed load-holding safety function, add a pilot-operated check valve at the cylinder ports.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.