The AirTAC AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F) is a genuine 5/2-way double solenoid (memory) solenoid valve with 32010F ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V320-10F is a 5/2-way double-solenoid directional control valve built on the 4V300 body, directing compressed air to double-acting cylinders and rotary actuators. Its defining feature is a memory spool: a momentary pulse to either solenoid shifts the valve, and the spool stays locked in that last-commanded position even when power is completely removed—no spring, no holding current, just balanced pressure and land friction. This makes it ideal for applications where the actuator must hold its end-of-stroke state without continuous coil energisation.
With a 3/8-inch PT port, a DC12V coil drawing just 2.5 W, and a terminal-box electrical entry, this valve suits moderate-flow circuits where low-voltage DC control is preferred. The 4V300 body delivers an effective area of 28.0 mm² (Cv 1.65) and can cycle at up to 4 times per second, providing crisp response for cylinders in the ~O50–80 mm bore range. The aluminium-alloy body weighs 400 g, carries an IP65 protection rating, and operates reliably from 0.15 to 0.8 MPa without requiring lubrication.
| Model | AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | 32010F |
| Exhaust port | 32010F |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -32010F | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Drives clamp and pusher cylinders on case packers and palletisers. The memory spool keeps the tooling in its last position during a machine pause or E-stop, so the sequence can resume without a re-homing cycle.
The DC12V coil and 2.5 W draw suit battery-powered lift tables, mobile compactors, and service-vehicle tooling. The double-solenoid memory holds the actuator position without draining the battery.
Operates large slide gates and diverter flaps in bulk-material handling. A brief 12 V pulse opens or closes the gate; the valve holds the spool position, so the gate stays put even if the control panel loses power.
Choose the 4V320-10F when your circuit needs a 5/2 double-solenoid valve with a 3/8-inch port and a 12 V DC supply. The memory function is the key differentiator from the spring-return 4V310: if you want the actuator to stay put after a short control pulse—without heating the coil or draining a battery—this is the correct configuration. The 3/8-inch port (Cv 1.65) fits cylinders roughly O50–80 mm; for smaller bores around O32–40 mm, stepping down to a 4V200 series (Cv 1.0) can save space and cost, while larger O100–125 mm cylinders usually demand the higher flow of a 4V400 (Cv 2.82).
When replacing an existing valve, match five points exactly: body size (4V300), function (double solenoid 5/2), port and thread (3/8 PT), coil voltage (DC12V), and electrical entry (terminal box). If you plan to group several valves on a common supply and exhaust, specify the 4V300 manifold base and confirm the station pitch. For a 5/3 center position—closed, exhaust, or pressure—switch to a 4V330x model, noting that the effective area drops to 21.3 mm² (Cv 1.25).
Quick checklist
The spool stays in the position it was last pulsed to—it does not spring back. The cylinder will remain pressurised on one side and hold its end-of-stroke position. This is a memory function, not a safety-rated load brake; if you are holding a suspended load, add a pilot-operated check valve at the cylinder ports.
No—the 4V320-10F is wound specifically for DC12V (2.5 W). Applying 24 V will overheat the coil and burn it out quickly. For a 24 V DC supply, order the 4V320-10B instead; it is mechanically identical but uses a 3.0 W DC24V coil.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.