verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F)

The AirTAC AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F) is a genuine 5/2-way double solenoid (memory) solenoid valve with 32010F ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port size32010F
  • Effective area28.0 mm²
  • Flow (Cv)1.65
  • Series4V300
$58.12 $65.62Save 11% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V320-10 stroke, mounting and version on one page All 4V320-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F)

The AirTAC 4V320-10F is a 5/2-way double-solenoid directional control valve built on the 4V300 body, directing compressed air to double-acting cylinders and rotary actuators. Its defining feature is a memory spool: a momentary pulse to either solenoid shifts the valve, and the spool stays locked in that last-commanded position even when power is completely removed—no spring, no holding current, just balanced pressure and land friction. This makes it ideal for applications where the actuator must hold its end-of-stroke state without continuous coil energisation.

With a 3/8-inch PT port, a DC12V coil drawing just 2.5 W, and a terminal-box electrical entry, this valve suits moderate-flow circuits where low-voltage DC control is preferred. The 4V300 body delivers an effective area of 28.0 mm² (Cv 1.65) and can cycle at up to 4 times per second, providing crisp response for cylinders in the ~O50–80 mm bore range. The aluminium-alloy body weighs 400 g, carries an IP65 protection rating, and operates reliably from 0.15 to 0.8 MPa without requiring lubrication.

AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F) Technical Specifications

ModelAirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F)
Series4V300 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port size32010F
Exhaust port32010F
Effective area (Cv)28.0 mm² (Cv 1.65)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency4 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight400 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area28.0 mm²
Flow coefficientCv 1.65
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F)

4VSolenoid valve, spool type, 4-series.
3Body size (4V300) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-32010FPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F) Is Used

conveyor_belt

Packaging & Palletising

Drives clamp and pusher cylinders on case packers and palletisers. The memory spool keeps the tooling in its last position during a machine pause or E-stop, so the sequence can resume without a re-homing cycle.

precision_manufacturing

Low-Voltage Mobile Equipment

The DC12V coil and 2.5 W draw suit battery-powered lift tables, mobile compactors, and service-vehicle tooling. The double-solenoid memory holds the actuator position without draining the battery.

settings_input_component

Pulse-Controlled Gate Valves

Operates large slide gates and diverter flaps in bulk-material handling. A brief 12 V pulse opens or closes the gate; the valve holds the spool position, so the gate stays put even if the control panel loses power.

Is the AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F) the Right Valve?

Choose the 4V320-10F when your circuit needs a 5/2 double-solenoid valve with a 3/8-inch port and a 12 V DC supply. The memory function is the key differentiator from the spring-return 4V310: if you want the actuator to stay put after a short control pulse—without heating the coil or draining a battery—this is the correct configuration. The 3/8-inch port (Cv 1.65) fits cylinders roughly O50–80 mm; for smaller bores around O32–40 mm, stepping down to a 4V200 series (Cv 1.0) can save space and cost, while larger O100–125 mm cylinders usually demand the higher flow of a 4V400 (Cv 2.82).

When replacing an existing valve, match five points exactly: body size (4V300), function (double solenoid 5/2), port and thread (3/8 PT), coil voltage (DC12V), and electrical entry (terminal box). If you plan to group several valves on a common supply and exhaust, specify the 4V300 manifold base and confirm the station pitch. For a 5/3 center position—closed, exhaust, or pressure—switch to a 4V330x model, noting that the effective area drops to 21.3 mm² (Cv 1.25).

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F) FAQ

The spool stays in the position it was last pulsed to—it does not spring back. The cylinder will remain pressurised on one side and hold its end-of-stroke position. This is a memory function, not a safety-rated load brake; if you are holding a suspended load, add a pilot-operated check valve at the cylinder ports.

No—the 4V320-10F is wound specifically for DC12V (2.5 W). Applying 24 V will overheat the coil and burn it out quickly. For a 24 V DC supply, order the 4V320-10B instead; it is mechanically identical but uses a 3.0 W DC24V coil.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V320-10F Solenoid Valve, 5/2-way, PT3/8, DC12V, terminal entry (4V32010F)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V32010F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.