The AirTAC 4V330E-10B Solenoid Valve, 5/3-way, exhaust center, PT3/8, DC24V, terminal entry (4V330E10B) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT3/8 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-10B is a 5/3-way double-solenoid directional control valve that directs compressed air to double-acting cylinders and actuators. Configured with a DC24V terminal-box coil drawing just 3.0 W, it shifts the spool to either end with a short pulse and returns both cylinder ports to exhaust when the valve is de-energised at center—allowing the actuator to float freely, which is useful for manual positioning or non-locking safety stops.
Built on the 4V300 aluminium body, this exhaust-center model provides an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and typically suits ~Ø50-80 mm cylinders. The sliding-column spool responds in 0.05 s or less, operates from 0.15-0.8 MPa with 40 µm filtered air, and carries an IP65 protection rating. At 450 g, it can be mounted individually or ganged on a manifold base.
| Model | AirTAC 4V330E-10B Solenoid Valve, 5/3-way, exhaust center, PT3/8, DC24V, terminal entry (4V330E10B) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
The exhaust center lets a clamp cylinder float at mid-position so an operator can manually align a part before the next cycle, then re-energises to lock it in place.
In pick-and-place or lift-assist arms, the 4V330E-10B dumps air at center to allow a smooth, gravity-assisted return or manual repositioning of the load without fighting trapped pressure.
When a guard opens, the valve returns to center and exhausts both cylinder ports, removing stored energy from the actuator circuit—a common requirement in light-duty press and machining safety layouts.
Choose the 4V330E-10B when your double-acting cylinder needs to coast to a stop or be moved by hand at mid-stroke—the exhaust center relieves pressure from both sides. If you need the piston to lock in place at center, select the closed-center 4V330C instead. For smaller cylinders around Ø32-40 mm, the 4V200 series (Cv 1.0) may be a more economical fit; for bores above Ø100 mm, step up to the 4V400 (Cv 2.82).
When replacing an existing valve, match five points: body size (4V300), function (5/3 exhaust-center), port size and thread (3/8" PT), coil voltage (DC24V), and electrical entry (terminal box). All 4V300 models share the same sub-base pattern, so you can swap a single valve on a manifold without re-plumbing.
Quick checklist
With a Cv of 1.25 and a 3/8" port, this valve is a good match for double-acting cylinders in the ~Ø50-80 mm range. It can drive larger bores, but cycle speed will drop; for consistent high-speed operation on Ø100 mm and above, consider the 4V400 series.
No—the exhaust center connects both cylinder ports to atmosphere at center, so the piston can move freely if an external force is applied. If you need the actuator to hold its position on power loss, choose the closed-center 4V330C model and add pilot-operated check valves for guaranteed load holding.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.