The AirTAC 4V330E-10FI Solenoid Valve, 5/3-way, exhaust center, PT3/8, DC12V, grommet entry (4V330E10FI) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT3/8 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-10FI is a 5/3-way double-solenoid directional valve that controls double-acting cylinders and actuators with an exhaust-center spool arrangement. When both solenoids are de-energised, the spool moves to the middle position, connecting cylinder ports A and B to exhaust while blocking the inlet—this lets the cylinder rod float freely, making it ideal for applications where the load must be moved manually or settle without air resistance once the cycle stops.
This specific model arrives pre-wired with a 0.5 m flying lead through a grommet entry and a 12 V DC coil drawing just 2.5 W, keeping control-panel heat low. Built on the 4V300 aluminium body, it delivers an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and a maximum cycling rate of 3 cycles per second, with an actuation response time of 0.05 s or less. The IP65-rated enclosure and 3/8-inch PT ports suit it to mid-bore pneumatic systems where the cylinder must be unloaded at rest.
| Model | AirTAC 4V330E-10FI Solenoid Valve, 5/3-way, exhaust center, PT3/8, DC12V, grommet entry (4V330E10FI) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
In pick-and-place or conveyor stop stations, the exhaust center lets the cylinder rod float so a gripper or stop blade can be pushed back by the product without fighting trapped air, preventing jam damage.
On assembly fixtures where an operator needs to slide a clamp into position by hand before locking, the 4V330E-10FI unloads both cylinder sides at neutral, allowing smooth manual repositioning.
Used on ~63 mm bore vertical guard doors, the exhaust center ensures the door can be lifted manually during an E-stop or power loss, meeting common safety-access requirements without adding a separate dump valve.
Choose the 4V330E-10FI when your circuit needs a 5/3 exhaust-center function on a 3/8-inch PT manifold or sub-base. The 4V300 body sits between the smaller 4V200 (Cv 1.0) and the larger 4V400 (Cv 2.82)—if you are driving a bore below 40 mm, stepping down to a 4V200 can improve cycle crispness, while a bore above 80 mm typically benefits from the higher flow of a 4V400.
When matching a replacement, verify all five points: body size (4V300), function (5/3 exhaust center, code 30E), port size and thread (3/8 PT), coil voltage (12 V DC), and electrical entry (grommet with flying lead). This valve can be used as a single unit or ganged on a common manifold base; if you later need a different center condition, the same manifold accepts 30C (closed) or 30P (pressure) versions without changing the plumbing layout.
Quick checklist
Both solenoids de-energise and the spool springs to the exhaust-center position. Inlet pressure is blocked, and both cylinder ports vent to atmosphere, so the piston rod can be moved freely by an external force. This is a normal control state, not a safety-rated holding function—if the load must be locked in place during a power failure, add a pilot-operated check valve or mechanical brake at the cylinder.
No—the 4V330E-10FI is factory-fitted with a 12 V DC coil (code F). Applying 24 V DC will burn the coil immediately. If your control system uses 24 V DC, order the 4V330E-10BI instead, which has the identical valve body and grommet entry but a 3.0 W DC24V coil.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.