The AirTAC 4V330P-10C Solenoid Valve, 5/3-way, pressure center, PT3/8, AC110V, terminal entry (4V330P10C) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT3/8 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330P-10C is a 5/3-way pneumatic directional control valve with a pressure center spool, designed to command double-acting cylinders and rotary actuators in mid-range automation. When both solenoids are de-energized, the spool shifts to its center position where both cylinder ports A and B are simultaneously supplied with inlet pressure, creating a balanced force that can be used for specific clamping or locking sequences. This model is configured with an AC110V coil drawing 4.5 VA and features a terminal box electrical entry with PT (Rc) tapered threads on its 3/8-inch supply and output ports.
Built on the 4V300 aluminum-alloy body platform, the valve offers an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and supports cylinders in the ~50–80 mm bore range. The sliding-column spool design achieves a response time of 0.05 seconds or less, operates within a 0.15–0.8 MPa pressure band, and carries an IP65 protection rating. Its double-solenoid architecture holds the last spool position on power loss, while the pressure-center function provides a distinct third state for applications requiring both sides of the actuator to be pressurized at rest.
| Model | AirTAC 4V330P-10C Solenoid Valve, 5/3-way, pressure center, PT3/8, AC110V, terminal entry (4V330P10C) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
In fixture clamping where both sides of a double-acting cylinder need to apply balanced pressure at rest, the 5/3 pressure-center spool pressurizes ports A and B simultaneously, holding the clamp with equal force without continuous solenoid power.
Used in pneumatic test stands where a cylinder must apply a controlled, balanced preload to a specimen. The pressure-center state provides equal pressure to both cylinder chambers, creating a net-zero force starting point for precision testing sequences.
In cleanroom or dusty environments, the pressure-center position keeps both cylinder ports slightly pressurized, preventing ambient air or particles from being drawn back into the cylinder or valve body during idle periods.
Choose the 4V330P-10C when your circuit needs a 5/3 pressure-center function on a 3/8-inch ported base—the center position pressurizes both cylinder ports, which can be useful for opposing-force applications or preventing contamination ingress. If your cylinder bore is below 40 mm, the smaller 4V200 series (Cv ~1.0) may offer a more responsive and economical match; for bores above 100 mm demanding higher flow, step up to the 4V400 body (Cv 2.82).
For a direct replacement, confirm all five points: the 4V300 body size, the 5/3 pressure-center function (30P), the 3/8-inch PT port (10), the AC110V coil voltage (C), and the standard terminal box entry. This valve can be mounted individually or ganged on a manifold base, and the manual override provides a non-locking push button for setup and troubleshooting.
AirtacDistr lists every 4V330P-10 order code with its price on one page at https://airtacdistr.com/products/airtac-4v330p-10-solenoid-valve
Quick checklist
In the center (de-energized) position, the 4V330P-10C connects both cylinder ports A and B to the inlet supply, pressurizing both sides of the double-acting cylinder simultaneously. This differs from the closed-center (30C) which blocks all ports, and the exhaust-center (30E) which vents both ports to atmosphere.
With an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10), the 4V330P-10C is typically a good match for double-acting cylinders in the ~50–80 mm bore range. The AC110V coil draws 4.5 VA, and the valve operates at up to 3 cycles per second.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.