verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C)

The AirTAC AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C) is a genuine 5/2-way single solenoid (spring return) solenoid valve with 41015C ports and an effective area of 48.0 mm² (Cv 2.82). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port size41015C
  • Effective area48.0 mm²
  • Flow (Cv)2.82
  • Series4V400
$48.82 $56.32Save 13% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V410-15 stroke, mounting and version on one page All 4V410-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C)

The AirTAC 4V410-15C is a 5/2-way single solenoid valve engineered for directing compressed air to double-acting cylinders and actuators. Its spring-return mechanism requires a constant AC110V signal to hold the shifted position; de-energising the coil instantly returns the spool to its home state, making it a predictable choice for circuits where the valve must default to a safe position on power loss.

Built on the largest 4V body, this model delivers a 48.0 mm2 effective area (Cv 2.82) and cycles at up to3 times per second. The terminal-box entry suits hard-wired installations, and the AC110V coil draws4.5 VA. At590 grams, it pairs well with pneumatic cylinders in the O80 to O125 mm range, providing a sub-0.05 s response for crisp actuation.

AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C) Technical Specifications

ModelAirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C)
Series4V400 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port size41015C
Exhaust port41015C
Effective area (Cv)48.0 mm² (Cv 2.82)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight590 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area48.0 mm²
Flow coefficientCv 2.82
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C)

4VSolenoid valve, spool type, 4-series.
4Body size (4V400) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-41015CPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V410 (single), 4V420 (double), 4V430C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C) Is Used

conveyor_belt

Large Part Ejectors

Controls a blast of air to eject heavy parts from a conveyor on packaging lines, where the spring return ensures the cylinder retracts if power is interrupted.

handyman

Workshop Air Systems

Directs air to a sizeable double-acting clamp on a workbench, with the AC110V terminal-box wiring fitting neatly into standard workshop electrical panels.

build

Press Guard Interlocks

Used in a pneumatic press circuit where the valve must spring back to a safe, blocked position when the guard is opened, cutting the AC110V signal.

Is the AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C) the Right Valve?

Select the4V410-15C when your double-acting cylinder falls in the O80-125 mm range and you need a single solenoid, spring-return action on an AC110V supply. If your cylinder is smaller, stepping down to a4V300 series valve with its lower Cv of1.65 avoids over-sizing and saves energy. The4V400 is the largest body in the4V family; for bores above125 mm or higher flow, consider moving to a larger valve series or ganging multiple units on a manifold.

For a drop-in replacement, match five points: body size (4V400), function (single solenoid5/2), port and thread (1/2in PT), coil voltage (AC110V), and electrical entry (terminal box). This ensures the same flow, wiring, and mounting footprint.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C) FAQ

With a Cv of 2.82 and48.0 mm2 effective area, it is sized for double-acting cylinders roughly O80 to O125 mm. The exact speed depends on your working pressure and tubing, but this body provides the flow capacity that mid-to-large bore cylinders demand.

The AC110V coil draws 4.5 VA inrush and holding. Ensure your control circuit can supply this. The terminal-box entry allows for a hard-wired connection, so use appropriately rated cable and follow local electrical codes for AC control voltages.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V410-15C Solenoid Valve, 5/2-way, PT1/2, AC110V, terminal entry (4V41015C)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V41015C and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.