AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI)

The AirTAC AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with 430E15FI ports and an effective area of 40.0 mm² (Cv 2.35). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Exhaust center
  • Port size430E15FI
  • Effective area40.0 mm²
  • Flow (Cv)2.35
  • Series4V400
$83.71 $91.21Save 8% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI)

The AirTAC 4V430E-15FI is a 5/3-way double-solenoid valve on the 4V400 body, configured with a 1/2-inch PT port, a DC12V coil, and a grommet-style electrical entry with a pre-wired 0.5 m flying lead. It directs compressed air to double-acting cylinders and actuators, and its exhaust center function means that when both solenoids are de-energized, the valve spool moves to the middle position where both cylinder ports are connected to exhaust. This allows the attached cylinder to float freely, making it ideal for applications where a load needs to be manually repositioned or where no holding force is required at center.

The 4V400 body provides a 40.0 mm² effective area (Cv 2.35) for 5/3 functions, suiting cylinders in the ~O80-125 mm range. The 2.5 W DC12V coil keeps power consumption low, and the valve achieves a response time of 0.05 seconds or less. With an IP65 protection rating and a robust aluminum-alloy body, it is built for demanding industrial environments.

AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI) Technical Specifications

ModelAirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI)
Series4V400 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Exhaust center
Port size430E15FI
Exhaust port430E15FI
Effective area (Cv)40.0 mm² (Cv 2.35)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight770 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area40.0 mm²
Flow coefficientCv 2.35
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI)

4VSolenoid valve, spool type, 4-series.
4Body size (4V400) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-430E15FIPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V410 (single), 4V420 (double), 4V430C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI) Is Used

handyman

Manual Load Positioning

In assembly stations where a large pneumatic clamp or lift must be freely moved by an operator between cycles, the 5/3 exhaust center allows the double-acting cylinder to float without residual pressure, enabling safe and easy manual repositioning.

local_shipping

Material Handling Gates

Controls large diverter gates on conveyors for O80-125 mm cylinders. The exhaust center permits the gate to be pushed open manually for clearing jams or maintenance without fighting trapped air pressure, enhancing operational safety.

build

Heavy Part Ejection

Used on a press ejector with a large cylinder, the 4V430E-15FI advances the cylinder to push a formed part out, then centers to exhaust both sides. This lets the ejector plate retract passively via the tool's return springs, simplifying the control circuit and reducing cycle time.

Is the AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI) the Right Valve?

Select the 4V430E-15FI when your application requires a large-bore double-acting cylinder to freely float at the center position, a common need in manual load positioning or when a cylinder must not hold pressure when idle. This 4V400 body is the largest in the 4V series; if you are driving a smaller cylinder (~O50-63 mm), stepping down to a 4V300 series valve with a Cv of 1.65 will provide a more appropriately sized and economical solution. For flow requirements exceeding the 4V400's capacity, consider moving to a larger valve series or a manifold assembly.

When replacing an existing valve, match these five points exactly: the 4V400 body size, the 5/3 exhaust center function, the 1/2-inch PT port, a DC12V coil voltage, and a grommet (flying lead) electrical entry. The DC12V grommet configuration is particularly useful in mobile or battery-powered equipment where 12 VDC is the primary control voltage and a simple flying-lead connection is preferred over a terminal box.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI) FAQ

With a 40.0 mm² effective area (Cv 2.35), this 4V400 valve is well-matched to double-acting cylinders in the ~O80 to O125 mm bore range. It provides sufficient flow for high-speed cycling of these larger cylinders at the standard 3 cycles/second maximum frequency.

In the de-energized center position, the 5/3 exhaust center spool connects both cylinder ports (A and B) to the exhaust ports, venting all pressure. This causes the cylinder to 'float' freely, allowing the piston rod to be moved by an external force. It is the correct choice when you need to manually position a load or when a tool must not be under pressure during a machine stop, but note that it does not hold a load in place.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC 4V430E-15FI Solenoid Valve, 5/3-way, exhaust center, PT1/2, DC12V, grommet entry (4V430E15FI)

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V430E15FI and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.